2-3: TAPE RUNNING ADJUSTMENT

MECHANICAL ADJUSTMENTS

2-2: CONFIRMATION AND ADJUSTMENT OF AUDIO/ CONTROL HEAD

When the Tape Running Mechanism does not work well, adjust the following items.

1.Playback the VHS Alignment Tape (JG001C or JG001E).

(Refer to SERVICING FIXTURE AND TOOLS)

2.Confirm that the reflected picture of stamp mark is appeared on the tape prior to P4 Post as shown in Fig. 2- 2-A.

a)When the reflected picture is distorted, turn the screw 1 clockwise until the distortion is disappeared.

b)When the reflected picture is not distorted, turn the screw 1 counterclockwise until little distortion is appeared, then adjust the a).

3.Turn the screw 2 to set the audio level to maximum.

4.Confirm that the bottom of the Audio/ Control Head and the bottom of the tape is shown in Fig. 2-2-C.

c)When the height is not correct, turn the screw 3 to adjust the height. Then, adjust the 1~3 again.

Audio/Control Head

Reflected picture of

Stamp Mark

P4 Post

Stamp Mark

Fig. 2-2-A

Audio/Control Head

31

2

4

Fig. 2-2-B

Audio/Control Head

Tape

2-3: TAPE RUNNING ADJUSTMENT

(X VALUE ADJUSTMENT)

1.Confirm and adjust the height of the Reel Disk.

(Refer to item 1-1)

2.Confirm and adjust the position of the Tension Post.

(Refer to item 1-2)

3.Adjust the Guide Roller. (Refer to item 2-1)

4.Confirm and adjust the Audio/Control Head.

(Refer to item 2-2)

5.Connect CH-1 of the oscilloscope to TP4001, CH-2 to TP4002 and CH-3 to HOT side of Audio Out Jack.

6.Playback the VHS Alignment Tape (JG001U or JG001V).

(Refer to SERVICING FIXTURE AND TOOLS)

7.Press and hold the TRACKING-AUTO button on the remote control more than 2 seconds to set tracking to center.

8.Set the X Value adjustment driver (JG153) to the 4 of Fig. 2-2-B. Adjust X value so that the envelope waveform output becomes maximum. Check if the relation between Audio and Envelope waveform becomes (1) or (2) of Fig. 2-1-A.

0.25±0.05mm

Fig. 2-2-C