NOTE FOR THE REPLACING OF MEMORY IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to ensure correct data settings while making reference to TABLE 1.
ADDRESS | DATA | ADDRESS | DATA | ADDRESS | DATA | ADDRESS | DATA | ADDRESS | DATA |
|
|
|
|
|
|
|
|
|
|
CC | F1 | D6 | 80 | E0 | 76 | EA | 51 | F4 | 41 |
|
|
|
|
|
|
|
|
|
|
CD | 44 | D7 | 00 | E1 | 5E | EB | 5F | F5 | 83 |
|
|
|
|
|
|
|
|
|
|
CE | 24 | D8 | 71 | E2 | 08 | EC | 09 | F6 | 3D |
|
|
|
|
|
|
|
|
|
|
CF | 88 | D9 | 9F | E3 | F0 | ED | F0 | F7 | 6B |
|
|
|
|
|
|
|
|
|
|
D0 | 92 | DA | 02 | E4 | 01 | EE | 05 | F8 | 0B |
|
|
|
|
|
|
|
|
|
|
D1 | 45 | DB | 0A | E5 | F3 | EF | F3 | F9 | 0C |
|
|
|
|
|
|
|
|
|
|
D2 | 00 | DC | 42 | E6 | 6C | F0 | 00 | FA | 04 |
|
|
|
|
|
|
|
|
|
|
D3 | 02 | DD | 35 | E7 | 2B | F1 | 2F | FB | 3A |
|
|
|
|
|
|
|
|
|
|
D4 | 09 | DE | A3 | E8 | 21 | F2 | DF | FC | 99 |
|
|
|
|
|
|
|
|
|
|
D5 | 03 | DF | 56 | E9 | 15 | F3 | 41 |
|
|
|
|
|
|
|
|
|
|
|
|
Table 1
1.Turn on the POWER and press both FF key and CH UP key on the set for more than 2 seconds.
2.ADDRESS and DATA should appear as FIG 1.
ADDRESS DATA
Fig. 1
3.ADDRESS is now selected and should "blink". Using the SET + or - keys on the remote, step through the ADDRESS until required ADDRESS to be changed is reached.
4.Press ENTER to select DATA. When DATA is selected, it will "blink".
5.Again, step through the DATA using SET + or - until required DATA value has been selected.
6.Pressing ENTER will take you back to ADDRESS for further selection if necessary.
7.Repeat steps 3 to 6 until all data has been checked.
8.When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
The unit will now have the correct DATA for the new MEMORY IC.