Specifications

 

 

 

 

 

 

 

 

 

Polar pattern:

cardioid

 

Frequency range:

20 to 20,000 Hz ± 1.5 dB from published curve

 

Sensitivity:

9 mV/Pa / -41 dBV re 1 V/Pa

 

Electrical impedance:

< 200 ohms

 

Recommended load impedance:

> 1000 ohms

 

Max. SPL for 0.5% THD:

112 Pa / 135 dB SPL with 0 dB preattenuation*)

 

 

355 Pa / 145 dB SPL with 10 dB preattenuation*)

 

 

1120 Pa / 155 dB SPL with 20 dB preattenuation*)

 

Equivalent noise level to IEC 60268-4 (A-weighted): 18 dB-A

 

Dynamic range:

117 dB max. (A-weighted)*)

 

Preattenuation pad:

switchable to 0 dB, -10 dB, -20 dB

 

Highpass filter:

switchable to flat or 12 dB/octave at 75 Hz or 150 Hz

 

Powering:

9 to 52 V phantom power to IEC 61938

 

Operating temperature:

-20°C to +60°C

 

Connector:

3-pin male XLR

 

Finish:

satin nickel plated

 

Size:

dia.: 19 mm (0.7 in.); length: 160 mm (6.3 in.)

 

Net/shipping weight:

125 g (4.4 oz.) / 760 g (1.7 lbs.)

*) Values measured with 48-V phantom power. Reduce by 2 dB for 24-V or 8 dB for 12-V phantom power.

This product conforms to the standards listed in the Declaration of Conformity. To order a free copy of the Declaration of Conformity, visit http://www.akg.com or contact sales@akg.com.

Frequency Response

Polar Diagram

 

75 Hz

150 Hz

C 451 B