XVC-1001-DC Guide to installation and operation
8
Power Consumption
The power rating of the openGear frame allows 125 watts to be
redistributed over 10 slots. A single slot may exceed 12 watts but the
overall power consumption shall not be above 125 watts.
The XVC-1001-DC dissipate 14 watts.
An openGear frame, when populated with Algogear cards only
(VNR-1000-SD, VNR-1000-HD, XVC-1001-UC, FRS-1002-MD...),
shall use no more than 8 slots.
Blank slot fillers can be used to block slots in an openGear frame. Contact
Algolith if you wish to get blank slot fillers for your openGear frame. A
warning message is affixed to the XVC-1001-DC card and other Algogear
cards to ensure the user is aware of the card’s power consumption when
installing new systems, or rearranging frame configurations.
openGear frame XVC Cards
Blocked frame slot

DO NOT REMOVE

ALGOGEAR
ALGOGEAR
ALGOGEAR
Card’s Identification
The XVC-1001-DC card is identified with a product label located near
the card’s front edge. When installed in a frame and powered, the card
displays the product name on a dot matrix display. See drawing below.
Input 1 status (DS2)
Card status (DS1)
Not used on XVC-1001-DC (DS3)
Not used on XVC-1001-DC (DS4)
Not used on XVC-1001-DC (DS5)
Card reference status (DS6)
Dot matrix display
Product label
ALGOGEAR
XVC-1001-DC
XVC1001D