XVC-1001-DC Guide to installation and operation
26
The Alarm Setup Window
Problems detected by the XVC-1001-DC card are transmitted as alarms
to the card’s LED, to the Dashboard interface, and to the optional SNMP
monitoring. The problems detected can be reported to the user as minor
alarms or critical alarms.
The Alarm Setup window allows the user to set the alarm level at which
many types of errors will be reported to the LEDs or to Dashboard, for
channel 1, for the reference signal and for the license key detection. The
alarm signals can also be disabled.
Minor: When the alarm level for a specific type or error is set to
minor, the card’s LED will report the problem with a yellow light and the
Dashboard interface with display a yellow circle with an error message
describing the problem.
Critical: When the alarm level for a specific type or error is set to critical,
the card’s LED will report the problem with a red light and the Dashboard
interface will display a red circle with an error message describing the
problem.
Carrier and video detection errors on input 1 are always reported as
critical and cannot be set otherwise.
The Alarm Setup settings are automatically saved to memory and are
recalled after power-up.
Alarms reported to card’s LED
Alarms reported to Dashboard
Input 1(DS2)
Card status (DS1)
Not used (DS3)
Not used (DS4)
Not used (DS5)
Card Reference (DS6)
ALGOGEAR