Dryer Slide Extension . . .

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the dryer(s) before servicing.

Close gas shut-off valve to gas dryer(s) before servicing.

Never start the dryer(s) with any guards/panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.

W001R1

1.Assemble coin slide extension, No. 503733, to top side of coin slide using two Phillips head screws and lockwashers, No. 03950. Tighten firmly.

2.Install slide extension modifier, No. 501796, as follows:

NOTE: Dryers equipped with Greenwald coin slides (except for Greenwald Comet Slide or Greenwald Tokette Slide) do not require the use of the slide extension modifier.

ESD Coin Slide – Mount slide extension modifier, No. 501796, to the underside of slide extension, No. 503733. Align the hole in the slide extension modifier with hole “A” in the slide extension and install self-tapping screw, No. 501086. Tighten firmly.

GREENWALD Comet Slide, GREENWALD Tokette Slide or MONARCH Coin Slide – Mount slide extension modifier, No. 501796, to the underside of slide extension, No. 503733. Align the hole in the slide extension modifier with hole “B” in the slide extension and install self- tapping screw, No. 501086. Tighten firmly.

501086

501796

SLIDE EXTENSION

SELF-TAPPING

MODIFIER

SCREW

 

 

HOLE "A"

 

 

HOLE "B"

03950

 

503733

PHILLIPS

 

SLIDE

HEAD

 

EXTENSION

SCREWS

 

 

AND

 

 

LOCKWASHERS

 

 

 

COIN

 

 

SLIDE

D019KE1C

 

 

3.Reinstall coin slide in dryer meter case.

4.CHECK DRYER OPERATION – Connect electrical power to dryer. Place required number of coins in coin slide. Push slide in, and observe through service door opening in meter case. The slide extension should be contacting the accumulator actuator arm and moving back with slide travel.

When slide is pushed all the way in, slide is retracted. Accumulator actuator arm should remain back until slide extension is moved forward and contacts actuator arm agian, returning arm to starting position.

5.After completing the dryer check, reinstall service door on top of meter case.

NOTE: When reinstalling service door, front of door must be inserted at about a 45° angle in order to engage notched tabs with internal rib at top of meter case.

 

ACCUMULATOR

 

 

ACTUATOR ARM

SLIDE

 

 

SLIDE

 

EXTENSION

 

MODIFIER

EXTENSION

 

 

COIN

 

 

SLIDE

 

 

D044KE1A

504523

9