Operating Instructions
Error Codes
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
•Disconnect electric power to the tumble dryer before servicing.
•Close gas
•Close steam valve to steam tumble dryer before servicing.
•Never start the tumble dryer with any guards/panels removed.
•Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumble dryer is properly grounded.
W002R1
Display | Definition | Corrective Action |
| Open thermistor error | • Check thermistor. Replace if inoperative. |
OP |
| • Check wiring diagram between control and thermistor. |
| Refer to wiring diagram for proper wiring. | |
|
| • Check control. Replace if inoperative. |
|
|
|
| Shorted thermistor error | • Check thermistor. Replace if inoperative. |
SH |
| • Check wiring between control and thermistor. Refer to |
| wiring diagram for proper wiring. | |
|
| • Check control. Replace if inoperative. |
|
|
|
AF - 1 | Airflow switch closed when cycle | • Check airflow switch. Replace if inoperative. |
started |
| |
|
| |
|
|
|
AF - 2 | Airflow switch failed to close after cycle | • Check airflow switch. Replace if inoperative. |
started |
| |
|
| |
|
|
|
| Bouncing Airflow Switch | • Check airflow switch to ensure that it is properly |
|
| aligned and securely mounted in the mounting bracket. |
|
| • Make sure airflow switch can open and close freely. |
AF |
| • Check installation and make sure there is adequate |
| airflow. | |
(Flashing) |
| |
| • Make sure exhaust is not blocked. | |
|
| |
|
| • Clean the lint screen. |
|
| • Replace airflow switch if inoperative. |
|
|
|
AF | Airflow Switch Closed when Resuming | • Allow up to 20 seconds for this condition to clear. |
Cycle | • Check if airflow switch opens at end of cycle. | |
(Solid) |
| • Replace airflow switch if inoperative. |
|
| |
|
|
|