Error Codes
Display Definition Corrective Action
OP
Open thermistor error Check thermistor. Replace if inoperative.
Check wiring diagram between control and thermistor.
Refer to wiring diagram for proper wiring.
Check control. Replace if inoperative.
SH
Shorted thermistor error Check thermistor. Replace if inoperative.
Check wiring between control and thermistor. Refer to
wiring diagram for proper wiring.
Check control. Replace if inoperative.
AF - 1 Airflow switch closed when cycle
started
Check airflow switch. Replace if inoperative.
AF - 2 Airflow switch failed to close after cycle
started
Check airflow switch. Replace if inoperative.
AF
(Flashing)
Bouncing Airflow Switch Check airflow switch to ensure that it is properly
aligned and securely mounted in the mounting bracket.
Make sure airflow switch can open and close freely.
Check installation and make sure there is adequate
airflow.
Make sure exhaust is not blocked.
Clean the lint screen.
Replace airflow switch if inoperative.
AF
(Solid)
Airflow Switch Closed when Resuming
Cycle
Allow up to 20 seconds for this condition to clear.
Check if airflow switch opens at end of cycle.
Replace airflow switch if inoperative.

To reduce the risk of electric shock, fire, explosion, serious injury or death:

• Disconnect electric power to the tumble dryer before servicing.

• Close gas shut-off valve to gas tumble dryer before servicing.

• Close steam valve to steam tumble dryer before servicing.

• Never start the tumble dryer with any guards/panels removed.

• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the tumble dryer is properly grounded.

W002R1
WARNING