Maintenance

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the tumble dryer before servicing.

Close gas shut-off valve to gas tumble dryer before servicing.

Close steam valve to steam tumble dryer before servicing.

Never start the tumble dryer with any guards/panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumble dryer is properly grounded.

W002R1

Bi-Annually Maintenance

Check mounting hardware for any loose nuts, bolts or screws.

Check gas connections for leakage.

Check for loose electrical connections.

Check steam connections for looseness and leakage.

Remove all front panels and vacuum, including coin drop mechanisms.

Check cylinder and front panel seals.

Inspect cabinet and inner panels for any damage, replace or repair as needed.

Clean burner tubes and orifice area of any lint buildup.

Annual Maintenance

Remove cylinder. Use a vacuum to clean lint from area around rear seal and idler assembly. Check seal and idler assembly for wear.

Remove burner tubes and clean using water and a brush.

70400101 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

25

Page 27
Image 27
Alliance Laundry Systems 602004144 manual Bi-Annually Maintenance, Annual Maintenance