© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Maintenance
70400101 (EN)
24
Quarterly Maintenance
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumble dryer before servicing.
• Close gas shut-off valve to gas tumble dryer before servicing.
• Close steam valve to steam tumble dryer before servicing.
• Never start the tumble dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumble dryer is properly grounded.
W002R1
WARN ING
Use a vacuum to clean air vents on
drive motors.
Use a vacuum to clean lint from rear
limit thermostat cover.
Check and clean steam coils, if
applicable.
Check flow of combustion and
ventilation air.
Check belt tension and condition.
Replace worn or cracked belts.