Operating Instructions

Door Open Mode

In Door Open Mode, the control turns off the heater and motor when the door is opened during a run cycle. The timer will continue to count down time and the IN USE LED is lit.

End of Cycle Mode

In End of Cycle Mode, a cycle is complete and the IN USE LED is off. The control remains in this mode until the door is opened or additional vend has been satisfied

Topoffs

Any time the control receives a coin drop pulse during a cycle it will add the programmed dry time to the time currently remaining in the cycle. The maximum cycle time is 99 minutes, the control will not add time beyond 99 minutes. The cool down time will not change.

NOTE: To change dipswitch settings refer to Installation Manual.

To Program a Short Test Cycle:

1.Unplug machine power cord.

2.Write down machine control dip switch settings, then set them all to the off position. Refer to Figure 6.

3.Plug machine in and start a cycle.

NOTE: With all control dip switches off, the total cycle time will be 2 minutes long (1 minute of heat and 1 minute of cool down).

4.Once all testing is complete, unplug machine and re-set dip switches to their original settings.

5.Plug machine in.

If the control receives a coin drop pulse during cool down the IN USE LED will flash briefly to indicate the coin input, the machine will exit cool down and it will start heating. The cycle time will be equal to the programmed dry time

Temperature Selector Switch

For five minutes after the control is powered up, there is a diagnostic feature that allows the temperature selector switches to be tested.

When the temperature selector is changed, the new setting is displayed by flashing the IN USE LED as follows:

High/Normal: 4 flashes

Medium/PP: 3 flashes

Low/Delicate: 2 flashes

No Heat: 1 flash

Error Codes

O 1 2 3 4 5 6 7 8

N

12345678

TMB2216N

Figure 6

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the tumble dryer before servicing.

Close gas shut-off valve to gas tumble dryer before servicing.

Close steam valve to steam tumble dryer before servicing.

Never start the tumble dryer with any guards/panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumble dryer is properly grounded.

W002R1

Display

Definition

Corrective Action

AF (Flashing)

Airflow switch opened/closed 5 or more

Check airflow switch. Replace if inoperative.

times in a running cycle.

 

 

 