Starting the Engine

Fourth Edition · First Printing

Operator's Manual

 

 

 

 

Starting the Engine

1At the ground controls, turn the key switch to the desired position.

2Be sure both ground and platform control red Emergency Stop buttons are pulled out to the on position.

Gasoline/LPG models

3Choose fuel by moving the fuel select switch to the desired position.

4Move the engine start toggle switch to either side. If the engine fails to start or dies, the restart delay will disable the start switch for 3 seconds.

Diesel models

3Move the glow plug switch to either side and hold for 3 to 5 seconds.

4Move the engine start toggle switch to either side. If the engine fails to start or dies, the restart delay will disable the start switch for 3 seconds.

All models

If engine fails to start after 15 seconds of cranking, determine the cause and repair any malfunction. Wait 60 seconds before trying to start again.

In cold conditions, 20°F / -6°C and below, warm the engine for 5 minutes before operating to prevent hydraulic system damage.

Operating Instructions

In extreme cold conditions, 0°F / -18°C and below, machines should be equipped with optional cold start kits. Attempting to start the engine when temperatures are below 0°F / -18°C may require the use of a booster battery.

Gasoline/LPG models: In cold conditions, 20°F / -6°C and below, the machine should be started on gasoline and warmed for 2 minutes, then switched to LPG. Warm engines can be started on LPG.

Emergency Stop

Push in either ground or platform red Emergency Stop button to the off position to stop all functions and turn the engine off.

Repair any function that operates when the red Emergency Stop button is pushed in.

Selecting and operating the ground controls will override the platform red Emergency Stop button.

Auxiliary Controls

Use auxiliary power if the primary power source (engine) fails.

1Turn the key switch to ground or platform control.

2Pull out the red Emergency Stop button to the on position.

3Press down the foot switch when operating the auxiliary controls from the platform.

4Simultaneously hold auxiliary power switch on and activate the desired function.

The drive and steer functions will not operate with auxiliary power.