Installation
Dimensional Clearances
Table 1 shows recommended minimum clearances on all sides of the
Recommended Minimum Clearances
Model | 18 |
| 30 | 33 | 40 |
|
| ||||
|
|
|
|
|
|
Minimum rear | 24 in. |
| 24 in. | 24 in. | 24 in. |
clearance | (600 mm) | (600 mm) | (600 mm) | (600 mm) | |
|
|
|
|
|
|
Minimum | 6 in. |
| 6 in. | 6 in. | 6 in. |
clearance | (150 mm) | (150 mm) | (150 mm) | (150 mm) | |
between |
|
|
|
|
|
machine and |
|
|
|
|
|
wall |
|
|
|
|
|
|
|
|
|
|
|
Minimum | 1 in. |
| 1 in. | 1.2 in. | 1.2 in. |
clearance | (25.4 |
| (25.4 | (33 mm) | (33 mm) |
between | mm) |
| mm) |
|
|
machines |
|
|
|
|
|
(side) |
|
|
|
|
|
|
|
|
|
|
|
Minimum front | 16.5 in. |
| 16.5 in. | 21 in. | 21 in. |
clearance (door | (419 mm) | (419 mm) | (533 mm) | (533 mm) | |
swing) |
|
|
|
|
|
|
|
|
|
|
|
|
| Table 1 |
|
|
Machine Foundation
Thoroughness of detail must be stressed with all foundation work to ensure a stable unit installation, eliminating possibilities of excessive vibration during extract.
CAUTION
Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.
W488
The
The standard installation does not require anchoring unless mandated by state or local codes.
Kinetic energy of the cylinder and dynamic loads on the floor or foundation are shown in Table 2.
Table 2 can be used as a reference when designing floors and foundations.
Floor Load Data
Model | 18 | 30 | 33 | 40 |
|
|
|
|
|
Kinetic | 1386 N/m | 2592 N/m | 2736 N/m | 4105 N/m |
energy of |
|
|
|
|
the |
|
|
|
|
cylinder |
|
|
|
|
|
|
|
|
|
Dynamic | 700 N/16 | 1000 N/ | 1200 N/ | 1200 N/ |
bottom | Hz | 16 Hz | 16 Hz | 16 Hz |
load |
|
|
|
|
|
|
|
|
|
|
| Table 2 |
|
|
9001909 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 15 |