Installation
Machine with Electric Heating
The green/yellow grounding clamp has to be connected to the grounding wire “PE”.
The green/yellow grounding clamp has to be connected to the grounding wire “PE”.
Electrical Specifications
|
| Voltage Designation |
|
| Standard |
|
| Electric Heat |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model | Code | Voltage | Cycle | Phase | Wire | Load Full Amps | Circuit Breaker | AWG/mm | kW | Load Full Amps | Circuit Breaker | AWG/mm | kW |
2 | 2 | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| P | 50/60 | 3 | 3+N+PE |
| Not available |
| 21 | 30 | 10/6.0 | 9 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| |
18 | Q | 50/60 | 3 | 3+PE |
| Not available |
| 27 | 30 | 10/6.0 | 9 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| X | 50/60 | 1/3 | 2/3+PE | 12 | 15 | 14/2.5 | 0.75 |
| Not available |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| P | 50/60 | 3 | 3+N+PE |
| Not available |
| 36 | 40 | 8/10.0 | 18 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| |
30 | Q | 50/60 | 3 | 3+PE |
| Not available |
| 49 | 60 | 6/16.0 | 18 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| X | 50/60 | 1/3 | 2/3+PE | 18 | 20 | 12/4.0 | 1.5 |
| Not available |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| P | 50/60 | 3 | 3+N+PE | 18 | 20 | 12/4.0 | 1.5 | 44 | 50 | 8/10.0 | 18 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
33 | Q | 50/60 | 3 | 3+PE | 18 | 20 | 12/4.0 | 1.5 | 63 | 70 | 4/25.0 | 18 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| X | 50/60 | 1/3 | 2/3+PE | 18 | 20 | 12/4.0 | 1.5 |
| Not available |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| P | 50/60 | 3 | 3+N+PE | 18 | 20 | 12/4.0 | 1.5 | 44 | 50 | 8/10.0 | 18 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
40 | Q | 50/60 | 3 | 3+PE | 18 | 20 | 12/4.0 | 1.5 | 63 | 70 | 4/25.0 | 18 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| X | 50/60 | 1/3 | 2/3+PE | 18 | 20 | 12/4.0 | 1.5 |
| Not available |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 6
After electrical installation is complete, run the machine through a test cycle and check for a clockwise basket rotation during the extract step. If rotation is not clockwise, disconnect the power from the machine and have a qualified electrician reverse any 2 motor leads at the AC drive terminal block.
9001909 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 25 |