Installation

5

1

A B C D E F G H I J K

AIR

FLOW

2

3

4

30°

1

2

EXHAUST AIR FLOW MAXIMUM

 

 

 

 

 

 

 

 

 

 

 

 

LENGTH OF DUCT 30 feet (9.1 m)

 

 

24 in. (61 cm)

 

 

 

 

 

MINIMUM

 

 

EXHAUST

CLEARANCE TO

 

 

OUTLET

ROOF/GROUND

D686I

HORIZONTAL EXHAUST INSTALLATION

 

 

D686I

NOTE: Where the exhaust duct pierces a

3

2 in. (5 cm) Minimum or Clearance per Local

combustible wall or ceiling, the opening must be

 

Codes

sized per local codes.

4

No Screen or Cap

Wall

5

Clean Out Cover Inspect Monthly

Figure 6

2

24 in. (61 cm)

MINIMUM

3

WARNING

To reduce the risk of fire and the accumulation of combustion gases, DO NOT

CLEARANCE TO

ROOF/GROUND

1

CONNECT TO DRYER

5

 

4

 

 

 

 

 

VERTICAL EXHAUST INSTALLATION

D753I

1Roof

2No Screen or Cap

3Wall

42 in. (5 cm) Minimum

5NOTE: Where the exhaust duct pierces a combustible wall or ceiling, an opening must be sized as shown or per local codes.

exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building.

W045

Figure 7

513220