Programming Vend Price

(For Models with Firmware ID Code “C2dS” and “CvdS”)

Setup Mode

NOTE: In SETUP Mode, certain machine functions can be configured. The settings in this mode are related to how the machine is equipped from the factory. Usually, these would not be changed in the field.

NOTE: Enter SETUP Mode through the PROGRAM Mode. Refer to Entering Program Mode.

1.Press (*) keypad. Display shows machine model

size (capacity). Displayed capacity must match machine size. Press (∧) keypad to change the capacity. (This should already be set correctly from the factory, and normally should never need to be changed).

2.Press START (Enter) keypad.

3.Display shows “FAr” or “CEL”.

NOTE: This option selects whether temperatures display in degrees Fahrenheit (F) or Celsius (C), if control is equipped with a temperature sensor.

Press the (∧) or (∨) keypad to change degrees “FAr” or “CEL”.

4.Press START (Enter) keypad.

5.If model displays “HEAt” or “noHt”, change the selection by pressing the (∧) or (∨) keypad. If model displays “CArd” or “COIn”, skip to step# 8.

6.Press START (Enter) keypad to continue to the next step.

7.“EFIL” or “nEFL” will display in certain models. “EFIL” means the capability to control an extra fill valve with programmable water level (same as regular fills) is enabled. Machine MUST be equipped with the extra valve for this to work properly. “nEFL” means the extra fill valve option is disabled or not installed on machine.

NOTE: If neither message displays, the extra fill capability is not present. If either message displays, changing the selection is an option by pressing the () or (∨) keypad. Press START (Enter) keypad to continue to the next option.

Programming

8.If model displays the message “CArd” or “COIn”, change the selection by pressing the (∧) or (∨) keypad.

9.Press START (Enter) keypad to continue to the next selection.

NOTE: Select “COIn used by accessory pay system. Contact the manufacturer of the accessory pay system if not working properly

10.“bEEP” or “nobP” will display in certain models. If “bEEP” is set, control will beep during Add Bleach (Supply 2) and at end of cycle after several seconds while displaying “dOnE”. If “nobP” displays, control will NOT beep during Add Bleach (Supply 2) or at end of cycle. This does not affect the short beep when a keypad is

pressed or a coin is inserted and it does not affect the beep during an alarm. Press the (∧) or (∨) keypad to change “bEEP”/“nobP” selection.

11.Press START (Enter) keypad to continue to next step.

12.“PtIn” means the control will display remaining

time in a cycle without fill and drain times. “EtIn” means the control will display estimated remaining time in a cycle including fill and drain time.

13.Press the (∧) or (∨) keypad to change “PtIn”/ “EtIn” selection.

14.Press START (Enter) keypad to continue to the next step.

NOTE: If machine is equipped with a card reader, or interfaces with a control/remote pay system, setting “con1”/ “dEno” and “con2”/ “dEno” equal to the vend start amount (“Strt”/ “Ant”) will allow starting with one pulse and is recommended. The card or central remote pay vend amount should match the “Strt”/ “Ant” setting.

15.Display shows “con1”, “dEno” next, then a number such as 25. This means that the coin 1 denomination is 25 cents for single coin meters. For example, a U.S. quarter coin meter would be set for 25 cents, or this would be the amount for one of the two denominations for a dual coin meter, such as a U.S. quarter for a dollar/quarter dual coin meter. The vend price programmed above will count down by this amount each time a coin is added.

16.Press the (∧) or (∨) keypad to decrease or increase this amount.

17.When correct, press START (Enter) keypad.