Installation
Vending
Meter Case
The factory mounted coin meter case does not include the service door lock, coin slide, coin drawer, coin drawer lock or keys. These parts must be ordered (at extra cost) according to the purchaser’s requirements direct from the manufacturer of your choice.
NOTE: On models with standard capacity meter case and high capacity meter case models starting with Serial Nos. beginning 1010, you have the option of using a screw type lock or a 1/4 turn lock on the meter case service door. If you choose to use a screw lock, then the special bracket (located inside the meter case) must be used. DO NOT use the special bracket if a 1/4 turn lock is used. High capacity meter case models with Serial Nos. beginning 0910 through 1010 use 1/4 turn lock only.
Coin Drawer Security (Models with standard capacity meter case and high capacity meter case models starting with Serial Nos. beginning 1010 only) – For additional security, drill out the two pilot holes on each side of the front of the meter case to 1/4 or 5/16 inch (6.4 or 7.9 mm) holes and install a bicycle lock through these holes.
NOTE: An 8 in. (20.32 cm) coin drawer is required for coin operated electronic control models with standard capacity meter case and high capacity meter case models starting with Serial Nos. beginning 1010. High capacity meter case models with Serial Nos. beginning 0910 through 1010 require a 7.21 in. (18.31 cm) coin drawer.
Slide Extension
(Coin Slide Models with standard capacity meter case and high capacity meter case models starting with Serial Nos. beginning 1010 only)
NOTE: High capacity meter case models with Serial Nos. beginning 0910 through 1010 require a coin slide with a switch installed on it.
1.Remove slide extension parts from parts accessories bag included in unit.
2.If installing a Greenwald coin slide, position extension lever (to be installed on extension bracket) with arm that has one star facing down. Refer to Figure 13.
Greenwald | Monarch or |
Coin Slide | ESD Coin Slide |
One Star | Two Stars |
|
TLW2088N
Figure 13
3.If installing a Monarch or ESD coin slide, position lever with arm that has two stars facing down. Refer to Figure 13.
4.Install extension lever with rounded corner facing away from extension bracket using bolt, one or two flat washers (shims) (use number of washers included in kit) and nut. Refer to Figure 14. Make sure washers are flat against bracket.
Spring | Bolt | One or Two |
Flat Washers (Shims) | ||
|
| Rounded Corner |
Loops |
| Nut |
|
|
Extension Bracket | Extension Lever |
| |
| TLW2089N |
Star(s) Facing Down
TLW2089N
Figure 14
5.Torque nut between 2 and 2.26 Nm (18 and 20
6.Install extension spring in bracket hole and hole in upper arm of lever. Refer to Figure 14.
7.Bend loops closed after installation.
8.Check to make sure the lever swings freely.
16 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 802734 |