Installation/Operation Supplement

Installation

Dimensional Clearances

Table 1 shows recommended minimum clearances on all sides of the washer-extractor.

Recommended Minimum Clearances

Model

18

30

 

 

 

Minimum rear clearance

24 in.

24 in.

(600 mm)

(600 mm)

 

 

 

 

Minimum clearance

6 in.

6 in.

between machine and wall

(150 mm)

(150 mm)

 

 

 

Minimum clearance

1 in.

1 in.

between machines (side)

(25.4 mm)

(25.4 mm)

 

 

 

Minimum front clearance

16.5 in.

16.5 in.

(door swing)

(419 mm)

(419 mm)

 

 

 

Table 1

Machine Foundation

Thoroughness of detail must be stressed with all foundation work to ensure a stable unit installation, eliminating possibilities of excessive vibration during extract.

CAUTION

Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.

W488

The washer-extractor must be placed on a smooth level surface so that the entire base of the machine is supported and rests on the mounting surface.

The standard installation does not require anchoring unless mandated by state or local codes.

Kinetic energy of the cylinder and dynamic loads on the floor or foundation are shown in Table 2.

Table 2 can be used as a reference when designing floors and foundations.

Floor Load Data

Model

18

30

 

 

 

Kinetic energy of the

1386 N/m

2592 N/m

cylinder

 

 

 

 

 

Dynamic bottom load

700 N/16 Hz

1000 N/16 Hz

 

 

 

Table 2