Installation/Operation Supplement

Electrical Specifications

 

 

Voltage Designation

 

 

Standard

 

 

Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Code

Voltage

Cycle

Phase

Wire

Load Full Amps

Circuit Breaker

AWG/mm

kW

Load Full Amps

Circuit Breaker

AWG/mm

kW

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380-415

50/60

3+N

3+N+PE

 

Not available

 

9

16

12/4.0

9

18

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

3

3+PE

 

Not available

 

17

25

10/6.0

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

6

16

14/2.5

0.75

 

Not available

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380-415

50/60

3+N

3+N+PE

 

Not available

 

28

50

8/10.0

18

30

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

3

3+PE

 

Not available

 

13

32

8/10.0

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

12

15

14/2.5

1.5

 

Not available

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3

12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9002062 (EN)