Installation

Dimensional Clearances

Refer to Figure 5 for recommended dimensional clearances.

1/2 in.

(13 mm)

6 in.

 

 

 

 

6 in.

(152 mm)

 

 

 

 

 

 

(152 mm) CAR10N

 

 

 

 

CAR10N

Figure 5

Machine Foundation

The machine may be placed on any level floor as long as floor will hold the weight of the machine.

Position the machine and level with shims or grout under the corners.

Refer to Table 3 for static loads on the floor.

Machine Anchoring

Bolting to floor is optional. To bolt down the machine, use 3/8 inch bolt holes located on the frame at the bottom of each corner. One quarter inch machine anchors should be used.

Floor Load Data

 

 

 

Specification

 

 

 

Static floor load

840 lbs.

 

(3.7 kN)

 

 

Static pressure

68 lbs-ft2

(3.3 kN-m2)

Table 3

F232212

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT