Installation

 

 

 

 

 

 

 

 

 

 

Electrical Specifications

 

 

 

 

 

 

 

 

 

 

 

Voltage Designation

 

 

Standard

 

 

 

 

 

 

 

 

 

 

Code

Voltage

Cycle

Phase

Wire

Full Load

Breaker

AWG

mm2

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

380-450

50

3

4

5

15

14

2.5

 

 

 

 

 

 

 

 

 

D

220-240

50

3

3

7

15

14

2.5

 

 

 

 

 

 

 

 

 

F

440-480

60

3

3

5

15

14

2.5

 

 

 

 

 

 

 

 

 

O

208-240

60

3

3

7

15

14

2.5

 

 

 

 

 

 

 

 

 

NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC 2001 edition.

Table 5

WARNING

Ensure that a ground wire from a proven earth ground is connected to the ground lug near the input power block on this machine. Without proper grounding, personal injury from electric shock could occur and machine malfunctions may be evident.

SW008

IMPORTANT: Installation shall conform with local codes or, in absence of local codes, with the National Electric Code ANSI/NFPA No. 70. Overloaded or undersized lines, or any low voltage condition will burn out motors and solenoid windings.

F232212

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT