When modifying a cycle, a time must be entered for each segment. To skip a segment or spin, set the time to “00” and press the Start key. Table 6 gives the time parameters for each segment and spin, as well as the allowable temperature range.
Time and Temperature Parameters
Function | Minimum | Maximum |
|
|
|
PreWash | 2 minutes | 30 minutes |
|
|
|
Wash | 2 minutes | 20 minutes |
|
|
|
Fill 1 | 2 minutes | 15 minutes |
|
|
|
Fill 2 | 2 minutes | 15 minutes |
|
|
|
Fill 3 | 2 minutes | 15 minutes |
|
|
|
Fill 4 | 2 minutes | 15 minutes |
|
|
|
Fill 5 | 2 minutes | 15 minutes |
|
|
|
Fill 6 | 2 minutes | 15 minutes |
|
|
|
Fill 7 | 2 minutes | 15 minutes |
|
|
|
Fill 8 | 2 minutes | 15 minutes |
|
|
|
Fill 9 | 2 minutes | 15 minutes |
|
|
|
Intermediate Spin* | 30 seconds | 240 seconds |
|
|
|
Final Spin** | 1 minute | 10 minutes |
|
|
|
Temperature | 75°F (25°C) | 200°F (93°C) |
|
|
|
*Programmed with wash segment through Fill 8.
**Programmed with Fill 9.
Table 6
NOTE: Spin times in cycle segments 1 – 10 are entered in seconds (30 to 240), and time for final spin in segment 11 is entered in minutes (1 to 10).
1.Press the Up key until the computer display shows the segment to be edited. Press the Start key.
2.Use the Up or Down key to select the desired segment time. Set this value to zero to skip the segment. Press the Start key.
Programming
NOTE: The computer does not count down the remaining cycle time during fills, drains, cool- down, or prior to first achieving the programmed heat temperature when heating. The computer resumes counting down cycle time once the programmed fill level is reached, when the machine has drained, and after a programmed heat temperature is reached.
3.If the
4.Use the Up or Down key to select the desired fill temperature. Refer to Table 7 for fill options.
Fill Temperature Options
Display | Fill Type |
|
|
CFIL | Cold Fill |
|
|
HFIL | Hot Fill |
|
|
bFIL | Warm Fill |
|
|
AFIL | Auxiliary Fill* |
|
|
*This is available only if the “SUP5”/“AFIL” setup option is set to “AFIL.”
Table 7
If the
5.Use the Up or Down key to select the desired fill level. Refer to Table 8.
Water Level Options
Display |
| Fill Level |
|
|
|
Lo |
| Low Level |
|
|
|
nEd |
| Medium Level |
|
|
|
HI |
| High Level |
|
|
|
| Table 8 |
F232123 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 23 |