Operation

Table 2 lists the various displays and what they mean. The operator should become familiar with these computer displays.

Display Indications

Display

Meaning

Display

Meaning

FPC3, bP3

Program identification code (ROM)

Lo

Low water level

 

 

These are examples only.

nEd

Medium water level

 

Hold

Wait...power has just been turned on.

HI

High water level

 

 

 

 

CY

Cycle (followed by two-digit number)

SUP1

Supply 1

 

 

 

 

tESt/CYC*

Test cycle selected.

SUP2

Supply 2

 

 

 

 

FAr

Degrees Fahrenheit

SUP3

Supply 3

 

 

 

 

CEL

Degrees Celsius

SUP4

Supply 4

 

 

 

 

HEAt

Auxiliary heat enabled.

SUP5

Supply 5 (SETUP option)

 

 

 

 

noHt

Auxiliary heat disabled.

SUP6

Supply 6 (supply 1 and 5)

 

 

 

 

tFIL

Temperature-controlled fill enabled.

SUP7

Supply 7 (supply 3 and 4)

 

 

 

 

ntFL

Temperature-controlled fill disabled.

SLo/For**

Gentle wash speed, forward direction

 

 

 

 

CooL

Automatic cool-down enabled.

SLo/rEv**

Gentle wash speed, reverse direction

 

 

 

 

noCL

Automatic cool-down disabled.

norn/For

Normal wash speed, forward direction

Ag 1

Agitation 1 selected (90% agitation).

norn/rEv

Normal wash speed, reverse direction

Ag 2

Agitation 2 selected (33% agitation).

drAI

Drain enabled.

 

 

 

 

Ag 3

Agitation 3 selected (10% agitation).

nodr

Drain disabled.

 

 

 

 

Ag 4

Agitation 4 selected (6.7% agitation).

dISt

Distribution (load balancing before extract)

 

 

 

 

AgSn

Agitation speed normal

SPIn/tInE*

Reads “SPIn” for one second, then “tInE” followed by

AgSL**

Agitation speed low

time for spin.

 

 

 

 

 

 

 

PUnP

Pump output enabled (future use only).

SPn1

Lowest of three spins

nPnP

Pump output disabled (future use only).

SPn2

Middle of three spins

PrE

PreWash segment (1st of 11 segments)

SPn3

Highest of three spins

 

 

 

 

UASH

Wash segment (2nd of 11 segments)

STOP

Stop routine

 

 

 

 

FIL1

First fill (3rd of 11 segments)

SdLY

Spin coast delay

 

 

 

 

FIL2

Second fill (4th of 11 segments)

donE

Cycle and stop routine have ended.

 

 

 

 

FIL3

Third fill (5th of 11 segments)

dFLt

Drive fault detected.

 

 

 

 

FIL4

Fourth fill (6th of 11 segments)

door

Door not properly closed.

 

 

 

 

FIL5

Fifth fill (7th of 11 segments)

bAL/FAIL*†

Balancing routine failed during test cycle after

 

 

FIL6

Sixth fill (8th of 11 segments)

7 attempts to balance load.

 

 

 

 

 

 

 

FIL7

Seventh fill (9th of 11 segments)

FILL/STOP*

Programmed water level not reached after

 

 

FIL8

Eighth fill (10th of 11 segments)

30 minutes.

 

 

 

 

 

 

 

FIL9

Ninth fill (11th of 11 segments)

FULL

The computer detects low water level or higher when

 

 

CFIL

Cold fill

none should be present.

 

 

 

 

 

 

 

bFIL

Warm fill (both hot and cold)

rotA

Computer detects possible rotation of motor when there

 

 

HFIL

Hot fill

should be none.

 

 

 

 

 

 

 

AFIL

Auxiliary fill (SETUP option)

tSFL

Temperature sensor failure or temperature out of range.

 

 

 

 

SPC?

Special test cycle function (if present, ignore)

bAL?

Special test cycle function (if present, ignore)

 

 

 

 

* Display indications separated by a slash represent a flashing display.

** For UW100VV and UW125VV models, the washer-extractor will operate at normal wash speed regardless of the speed settings.

† This occurs only in the TEST cycle and only if the AC inverter drive balance detection is used. If the AC inverter drive balance detection is not used, this will NOT appear during the TEST cycle (note, there are two types of balance systems).

Table 2

14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232123