Installation

UWAV Pocket Hardmount General Specifications (Continued)

Specifications

 

35

60

80

100

125

 

 

 

 

 

 

 

 

 

 

 

 

Drive Train Information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of motors in drive train

 

 

1

 

1

 

1

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

Drive motor power, hp (kW)

 

2.3

(1.7)

2.9

(2.2)

5.0

(3.7)

5.0

(3.7)

7.5

(5.6)

 

 

 

 

 

 

 

 

 

 

Cylinder Speeds / Centrifugal Force Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2 Wash/reverse, rpm (g)

 

26 (.25)

26 (.31)

26 (.35)

26 (.35)

26 (.40)

 

 

 

 

 

 

 

 

Wash/reverse, rpm (g)

 

 

42 (.66)

40 (.73)

40 (.82)

40 (.82)

37 (.82)

 

 

 

 

 

 

 

 

Distribution, rpm (g)

 

 

83 (2.57)

71 (2.29)

73 (2.57)

70 (2.50)

62 (2.29)

 

 

 

 

 

 

 

High extract 1, rpm (g)

 

328 (40)

297 (40)

280 (40)

280 (40)

260 (40)

 

 

 

 

 

 

 

 

 

 

 

 

High extract 2, rpm (g)

 

534

(106)

483

(106)

456

(106)

456

(106)

422

(106)

 

 

 

 

 

 

 

 

 

 

 

 

High extract 3, rpm (g)

 

656

(160)

594

(160)

560

(160)

560

(160)

518

(160)

 

 

 

 

 

 

 

 

 

 

 

 

Balance Detection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vibration safety switch installed

 

N/A

STD

STD

STD

STD

 

 

 

 

 

 

 

Safety switch gap setting, in (mm)*

 

N/A

.008 (.20) GO

.008 (.20) GO

.008 (.20) GO

.006 (.15) GO

 

 

 

 

 

 

.010 (.25) NO-GO

.010 (.25) NO-GO

.010 (.25) NO-GO

.008 (.20) NO-GO

 

 

 

 

 

 

 

 

 

 

 

 

Direct Steam Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam inlet connection size, in

 

 

.5

 

.5

 

.5

 

.5

.75

 

 

 

 

 

 

 

 

 

 

 

 

Number of steam inlets

 

 

1

 

1

 

1

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam required to

 

LOW

 

2.1

(1.5)

3.3

(2.4)

4.6

(3.3)

5.7

(4.1)

6.7

(4.9)

raise bath

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature

 

MED

 

2.3

(1.7)

3.7

(2.6)

5.2

(3.8)

6.5

(4.7)

7.8

(5.6)

10°F, lb (10°C, kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

2.7

(1.9)

4.1

(2.9)

6.1

(4.4)

7.6

(5.5)

9.1

(6.6)

 

 

 

 

 

 

 

 

 

 

 

Average consumption per cycle, bhp (kg)

 

1.4 (21.4)

2.1 (33.4)

3.1 (48.4)

3.8 (60.4)

4.6 (72.0)

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total electrical heating capacity, kW

 

15.6

25.2

37.8

37.8

50.4

 

 

 

 

 

 

 

 

 

 

 

Number of electrical heating elements

 

 

6

 

6

 

9

 

9

12

 

 

 

 

 

 

 

Electrical heating element size, kW

 

2.6

4.2

4.2

4.2

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

Time required to

 

LOW

 

2.4

(3.6)

2.4

(3.7)

2.2

(3.4)

2.8

(4.2)

2.5

(3.8)

raise bath

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature

 

MED

 

2.7

(4.1)

2.7

(4.1)

2.5

(3.9)

3.2

(4.8)

2.9

(4.4)

10°F, min (10°C,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

min)

 

HIGH

 

3.1

(4.7)

3.0

(4.6)

3.0

(4.5)

3.7

(5.6)

3.4

(5.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Gap setting should be made with “GO-NO-GO” type feeler gauge.

F232228

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9