Installation
UWAV Pocket Hardmount General Specifications (Continued)
Specifications |
| 35 | 60 | 80 | 100 | 125 | |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
Drive Train Information |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |||
Number of motors in drive train |
|
| 1 |
| 1 |
| 1 |
| 1 |
| 1 | ||
|
|
|
|
|
|
|
|
|
|
|
| ||
Drive motor power, hp (kW) |
| 2.3 | (1.7) | 2.9 | (2.2) | 5.0 | (3.7) | 5.0 | (3.7) | 7.5 | (5.6) | ||
|
|
|
|
|
|
|
|
|
| ||||
Cylinder Speeds / Centrifugal Force Data |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| ||||||||
1/2 Wash/reverse, rpm (g) |
| 26 (.25) | 26 (.31) | 26 (.35) | 26 (.35) | 26 (.40) | |||||||
|
|
|
|
|
|
|
| ||||||
Wash/reverse, rpm (g) |
|
| 42 (.66) | 40 (.73) | 40 (.82) | 40 (.82) | 37 (.82) | ||||||
|
|
|
|
|
|
|
| ||||||
Distribution, rpm (g) |
|
| 83 (2.57) | 71 (2.29) | 73 (2.57) | 70 (2.50) | 62 (2.29) | ||||||
|
|
|
|
|
|
| |||||||
High extract 1, rpm (g) |
| 328 (40) | 297 (40) | 280 (40) | 280 (40) | 260 (40) | |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
High extract 2, rpm (g) |
| 534 | (106) | 483 | (106) | 456 | (106) | 456 | (106) | 422 | (106) | ||
|
|
|
|
|
|
|
|
|
|
|
| ||
High extract 3, rpm (g) |
| 656 | (160) | 594 | (160) | 560 | (160) | 560 | (160) | 518 | (160) | ||
|
|
|
|
|
|
|
|
|
|
|
| ||
Balance Detection |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| ||||||||
Vibration safety switch installed |
| N/A | STD | STD | STD | STD | |||||||
|
|
|
|
|
|
| |||||||
Safety switch gap setting, in (mm)* |
| N/A | .008 (.20) GO | .008 (.20) GO | .008 (.20) GO | .006 (.15) GO | |||||||
|
|
|
|
|
| .010 (.25) | .010 (.25) | .010 (.25) | .008 (.20) | ||||
|
|
|
|
|
|
|
|
|
|
|
| ||
Direct Steam Heating (Optional) |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||||
Steam inlet connection size, in |
|
| .5 |
| .5 |
| .5 |
| .5 | .75 | |||
|
|
|
|
|
|
|
|
|
|
|
| ||
Number of steam inlets |
|
| 1 |
| 1 |
| 1 |
| 1 |
| 1 | ||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Steam required to |
| LOW |
| 2.1 | (1.5) | 3.3 | (2.4) | 4.6 | (3.3) | 5.7 | (4.1) | 6.7 | (4.9) |
raise bath |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
temperature |
| MED |
| 2.3 | (1.7) | 3.7 | (2.6) | 5.2 | (3.8) | 6.5 | (4.7) | 7.8 | (5.6) |
10°F, lb (10°C, kg) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH |
| 2.7 | (1.9) | 4.1 | (2.9) | 6.1 | (4.4) | 7.6 | (5.5) | 9.1 | (6.6) | |
|
|
| |||||||||||
|
|
|
|
|
|
|
| ||||||
Average consumption per cycle, bhp (kg) |
| 1.4 (21.4) | 2.1 (33.4) | 3.1 (48.4) | 3.8 (60.4) | 4.6 (72.0) | |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
Electrical Heating (Optional) |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| ||||||||
Total electrical heating capacity, kW |
| 15.6 | 25.2 | 37.8 | 37.8 | 50.4 | |||||||
|
|
|
|
|
|
|
|
|
|
| |||
Number of electrical heating elements |
|
| 6 |
| 6 |
| 9 |
| 9 | 12 | |||
|
|
|
|
|
|
| |||||||
Electrical heating element size, kW |
| 2.6 | 4.2 | 4.2 | 4.2 | 4.2 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Time required to |
| LOW |
| 2.4 | (3.6) | 2.4 | (3.7) | 2.2 | (3.4) | 2.8 | (4.2) | 2.5 | (3.8) |
raise bath |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
temperature |
| MED |
| 2.7 | (4.1) | 2.7 | (4.1) | 2.5 | (3.9) | 3.2 | (4.8) | 2.9 | (4.4) |
10°F, min (10°C, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
min) |
| HIGH |
| 3.1 | (4.7) | 3.0 | (4.6) | 3.0 | (4.5) | 3.7 | (5.6) | 3.4 | (5.1) |
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
* Gap setting should be made with
F232228 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 9 |