Specifications and Dimensions
The external supply connection is located on the rear panel of the control module. It houses a terminal strip which furnishes supply output signals for the chemical injection supply pumps. Refer to Figure 21 for examples of applicable decals.
Terminals SUPPLY 1 through SUPPLY 5 provide
200 – 240VAC fused at 500mA. These terminals may be used to provide signals to the chemical injection system but must not be used to provide power to the pump. Do not attempt to increase fuse rating as this may cause damage to the
An external chemical injection system requiring 200 – 240VAC can be powered through LINE 1 and LINE 2 on the external supply terminal strip on UWAVX and UWAVQ models. Any chemical injection system used with UWAVN or UWAVP models must be powered by a separate external power source.
Any injection system pump which requires 110VAC must be powered by a separate external power source.
CAUTION
Attempting to obtain 110VAC by using L1 or L2 with the common may damage laundry machine circuitry and/or the chemical injection system. Using a 240VAC power wire in the washer- extractor and an earth ground to obtain 110VAC could cause microprocessor problems.
SW028
Refer to Chemical Injection Supply System instructions for operational details.
P AND N VOLTAGE MODELS (AVP AND AVN)
X (AVX) AND Q (AVQ) VOLTAGE MODELS
PHM554N
Figure 21
32 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232228 |