Installation

Floor Load Data

 

 

 

 

 

 

 

 

 

 

 

UW A-Control, Variable Speed Pocket Hardmount

 

 

 

 

 

 

 

Specifications

UW35AV 160g

UW60AV 160g

UW80AV 160g

UW100AV 160g

UW125AV 160g

 

 

 

 

 

 

Static Load Pressure, kN/sq m

6.33

7.77

8.46

9.18

9.16

 

 

 

 

 

 

Static Load Pressure, lbs/sq ft

132

162

177

192

191

 

 

 

 

 

 

Total Dynamic Load, kN*

5.0

8.6

11.4

14.2

17.8

 

 

 

 

 

 

Total Dynamic Load, lbs*

1122

1922

2562

3203

3996

 

 

 

 

 

 

Dynamic Load Pressure, kN/sq m

7.1

10.3

9.8

12.3

11.9

 

 

 

 

 

 

Dynamic Load Pressure, lbs/sq ft

149

216

205

256

249

 

 

 

 

 

 

Dynamic Load Freq, Hz

10.9

9.9

9.3

9.3

8.6

 

 

 

 

 

 

Maximum Vertical Load, kN†

8.5

13.7

19.1

22.3

28.3

 

 

 

 

 

 

Maximum Vertical Load, lbs†

1917

3073

3073

5002

6358

 

 

 

 

 

 

Minimum Vertical Load, kN††

1.45

3.43

3.43

6.24

7.27

 

 

 

 

 

 

Minimum Vertical Load, lbs††

326.62

770.90

823.07

1403.64

1634.52

 

 

 

 

 

 

Maximum Moment about Machine Base,

3.9

8.2

11.3

14.1

18.0

kN-m

 

 

 

 

 

 

 

 

 

 

 

Maximum Moment about Machine Base,

2893

6053

8322

10,403

13,243

lb-ft

 

 

 

 

 

 

 

 

 

 

 

Table 2

Acting in the downward direction against the floor.

††Acting in the upward direction against the floor.

F232228

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

13