Specifications and Dimensions

Mounting Bolt Installation Requirements

A bolt kit consisting of eight bolts is available as an option. The UW35AV uses 5/8-11 x 8 inch bolts. The UW60AV, UW80AV, UW100AV and UW125AV use 3/4-10 x 8 inch bolts. The bolts should be embedded in a 3500 psi minimum reinforced concrete floor that is a minimum of 12 inches thick. Use the mounting bolt layouts in Figure 8 and Figure 9. (The front of the washer-extractor is the bottom of each diagram.)

The threaded end of the bolts should extend 2 inches above the surface of the floor.

Refer to Figure 8 for a typical installation of individual mounting bolts.

0.75 in.

1

2

(19 mm)

 

 

2 in.

(51 mm)

8in.

(203 mm)

PHM178N

1Frame

2Grout

Figure 8

Abolt-locator fixture or rebar frame is available as an option. This rigid welded assembly made of reinforcing rod and mounting bolts is designed to be embedded in concrete. Refer to Figure 9.

1

2

3

4

PHM179N

1Machine Base

2Mounting Bolt Threads

3Grouting

4Reinforcing Rod

Figure 9

18

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232228