Specifications and Dimensions
Water Connection Requirements
WARNING
To avoid personal injury, recommended inlet water temperature should be no higher than 125° Fahrenheit (51° Celsius).
W709
UWAV Pocket Hardmount
Water Supply Information
Specifications | 35 |
| 60 | 80/100 | 125 |
|
|
|
|
|
|
Number of main fill water inlets | 2 |
| 2 | 2 | 2 |
|
|
|
|
|
|
Main fill water inlet size, in (mm) | 0.5 (12.7) |
| 0.75 (19) | 0.75 (19) | 1 (25.4) |
|
|
|
|
|
|
Recommended pressure psi (bar) |
|
| |||
|
|
|
|
| |
Inlet flow capacity (80 psi), | 14 (53) |
| 25 (95) | 25 (95) | 50 (189) |
gal/min (l/min) |
|
|
|
|
|
|
|
|
|
|
|
|
| Table 5 |
|
|
Connections should be supplied by hot and cold water lines of at least the sizes shown in Table 6. Installation of additional machines will require proportionately larger water lines.
To connect water service to machine with rubber hoses, use the following procedure:
1.Before installing hoses, flush the water system for at least two minutes.
2.Check filters in the
3.Hang the hoses in a large loop; do not allow them to kink.
If additional hose lengths are needed, use flexible hoses with screen filters. Each hose should have a screen filter installed to keep rust and other foreign particles out of the water inlet valves.
Pressure of 30 – 85 psi (2 – 5.7 bar) provides best performance. Although the