Specifications and Dimensions

Suitable air cushions should be installed in supply lines to prevent “hammering.” Refer to Figure 16.

UWAV Pocket Hardmount

Water Supply Line Sizing

Model

of Machines

Main

Hot/Cold

 

Number

Supply Line Size, in (mm)

 

 

 

 

 

1

1 (25)

0.75 (19)

 

 

 

 

35

2

1.5 (38)

1 (25)

 

 

 

3

2 (50)

1.25 (32)

 

 

4

2 (50)

1.5 (38)

 

 

 

 

 

1

1.25 (32)

1 (25)

 

 

 

 

60

2

2 (50)

1.25 (32)

 

 

 

3

2 (50)

1.5 (38)

 

 

 

 

 

 

4

2.5 (64)

2 (50)

 

 

 

 

 

1

1 (25)

0.75 (20)

 

 

 

 

80

2

1.5 (38)

1 (25)

 

 

 

3

1.5 (38)

1.25 (32)

 

 

4

2 (50)

1.5 (38)

 

1

1 (25)

0.75 (20)

 

 

 

 

100

2

1.5 (38)

1 (25)

 

 

 

3

1.5 (38)

1.25 (32)

 

 

 

 

 

 

4

2 (50)

1.5 (38)

 

 

 

 

 

1

1.5 (38)

1 (25)

 

 

 

 

125

2

2 (50)

1.5 (38)

 

 

 

3

2.5 (64)

2 (50)

 

 

 

 

 

 

4

2.5 (64)

2 (50)

 

 

Table 6

 

2

1

PHM184N

1Water Supply Faucets

2Air Cushions (Risers)

Figure 16

24

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232228