Specifications and Dimensions

UWAV Pocket Hardmount

Electrical Specifications

 

 

Voltage Designation

 

 

 

 

Standard

 

 

 

 

 

 

 

 

 

 

 

 

Model

Code

Voltage

Cycle

Phase

Wire

LoadFull Amps

Breaker

 

AWG

2

 

 

 

 

 

 

 

 

 

 

mm

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50-60

3

3

4

15

 

14

3x2.5

35

 

 

 

 

 

 

 

 

 

 

P

380-415

50-60

3

3

4

15

 

14

3x2.5

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50-60

1/3

2/3

9

15

 

14

2/3x2.5

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50-60

3

3

4

15

 

14

3x2.5

60

 

 

 

 

 

 

 

 

 

 

P

380-415

50-60

3

3

4

15

 

14

3x2.5

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50-60

1/3

2/3

10

15

 

14

2/3x2.5

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50-60

3

3

6

15

 

14

3x2.5

80

 

 

 

 

 

 

 

 

 

 

P

380-415

50-60

3

3

6

15

 

14

3x2.5

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50-60

3

3

9

25

 

14

3x6

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50-60

3

3

6

15

 

14

3x2.5

100

 

 

 

 

 

 

 

 

 

 

P

380-415

50-60

3

3

6

15

 

14

3x2.5

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50-60

3

3

10

25

 

10

3x6

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50-60

3

3

7

15

 

14

3x6

125

 

 

 

 

 

 

 

 

 

 

P

380-415

50-60

3

3

7

15

 

14

3x6

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50-60

3

3

13

25

 

10

3x6

 

 

 

 

 

 

 

 

 

 

 

Note: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.