Specifications and Dimensions
Connecting External Liquid Supplies to the
1.Remove knockout from supply dispenser. Refer to Figure 19. Plugs are assembled inside the tubing ring.
2.Install PG connector in hole with strain reliefs, included in the seal nut.
3.Insert tubes through base. Do not remove cups. Tube should extend into the plastic cup, with the exception of the softener tube, which should be routed to the outside of the cup.
4.Tighten the seal nut to prevent tubing from escaping the assembly.
The UW35AV – UW125AV have a polypropylene supply dispenser. Refer to Figure 20.
Do not attempt to make chemical injection electrical connections to points other than those provided specifically for that purpose by the factory.
Chemical Injection Supply System
Specifications | AV |
|
|
Number of dry supply compartments | 5 |
|
|
Number of liquid supply connections | 5 |
|
|
Liquid supply connection size, in (mm) | .5 (12.7) |
|
|
1
2
3
4
5
6
|
|
| PHM553N |
|
|
| PHM553N |
1 | Strain Relief for Liquid Chemical Supply Lines | 4 | Dry Supply Cups |
2 | Supply Dispenser Lid | 5 | Dry Supply Insert |
3 | Nozzles | 6 | Polypropylene Supply Dispenser |
IMPORTANT: Do not attach anything to nozzles. Air gap must be maintained.
Figure 20
F232228 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 31 |