Specifications and Dimensions

The washer-extractor should be connected to an

 

 

 

 

 

 

 

 

1

 

 

 

individual branch circuit not shared with lighting or

 

 

2

 

 

 

 

 

other equipment.

 

 

 

 

 

 

 

The connection should be shielded in a liquid-tight or

 

 

 

Connections to

 

 

 

 

 

 

Control Module

approved flexible conduit with proper conductors of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

correct size installed in accordance with the National

 

 

 

 

 

 

 

Electric Code or other applicable codes. The

 

 

 

 

 

 

 

connection must be made by a qualified electrician

 

 

 

 

 

 

 

 

 

 

 

 

 

 

using the wiring diagram provided with the washer-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

extractor.

 

 

 

 

 

 

 

Use wire sizes indicated in the Electrical

 

 

 

 

 

 

 

 

 

 

(L1)

(L2)

(L3)

Specifications chart for runs up to 50 feet (15 m). Use

 

 

 

next larger size for runs of 50 to 100 feet (15 to 30 m).

 

 

 

R

S

T

Use two sizes larger for runs greater than 100 feet

 

 

 

Black

Blue

Red

(30 m).

 

 

 

 

 

 

PHM572N

1

 

 

Grounding Lug: Connect to proven earth

For personal safety and for proper operation, the

 

 

 

 

 

ground

 

 

 

washer-extractor must be grounded in accordance with

2

 

 

Power Input Block

 

 

state and local codes. If such codes are not available,

 

 

 

 

 

 

 

grounding must conform with the National Electric

 

 

 

 

Figure 17

 

 

Code, article 250-95. The ground connection must be

 

 

 

 

 

 

 

 

 

 

 

 

 

made to a proven earth ground, not to conduit or water

 

 

 

 

 

 

 

pipes.

 

 

 

 

 

 

 

If a delta supply system is used, the high leg should be connected to L3.

After electrical installation is complete, run the machine through a test cycle and check for a clockwise basket rotation during the extract step. If rotation is not clockwise, disconnect the power from the machine and have a qualified electrician reverse any 2 motor leads at the AC drive terminal block.

F232228

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

27