Programming

Permanent Diagnostic Test Cycle

 

Control Test

 

 

Warm fill to low water level

Display flashes “bFIL”/“LO” (WASH LED on), no agitation

 

 

 

Outputs: Motor OFF, Drain closed, hot fill on, cold fill on

 

 

Pause after reaching low water

Display shows “LO” (no flashing), LOW water level dot ON, no agitation (keypad WASH

level

LED on); pauses until operator presses (∧) key

 

 

 

Outputs: Motor OFF, Drain closed

 

 

Drain (can advance to next step

Display shows “drAI”, no agitation (keypad WASH LED on)

by pressing (∧) key here)

 

Outputs: Motor OFF, Drain open

 

 

 

Cold fill to medium level

Display flashes “CFIL”/“nEd” (keypad WASH LED on), no agitation.

 

Outputs: Motor OFF, Drain closed, cold fill on

 

 

Pause after reaching medium

Display shows “nEd” (no flashing), LOW and MEDIUM water level dots ON no agitation

water level

(keypad WASH LED on); pauses until operator presses (∧) key

 

 

 

Outputs: Motor OFF, Drain closed

 

 

Hot fill to high level

Display flashes “HFIL”/“HI” (keypad WASH LED on), no agitation.

 

 

 

Outputs: Motor OFF, Drain closed, hot fill on

 

 

Pause after reaching high water

Display shows “HI” (no flashing), LOW, MEDIUM, and HIGH water level dots ON, no

level

agitation (keypad WASH LED on); pauses until operator presses (∧) key

 

 

 

Outputs: Motor OFF, Drain closed

 

 

Heat to 110°F (45°C)

Display flashes “HEAt” and the temperature inside the machine while agitating in forward

SKIPS THIS STEP if machine

and reverse; continues until temperature reaches 104°F (40°C), then advances to next step.

does not have heat capability

(keypad WASH LED on)

(“noHt” selected in Setup

 

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds

Mode)

and repeats; Drain closed; Heat ON UNTIL 104°F (40°C) reached

 

 

 

Extra supply / fill spare –

Display flashes ‘ESUP’ / ‘EFIL’ (keypad WASH LED on)

5 seconds (depends on setup)

 

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds

 

 

and repeats; Drain closed; ‘AF’ output ON.

 

 

Supply 1: 5 seconds (Heat

Display shows ‘SUP1’ (keypad WASH LED on)

signal also on (IF at least low

 

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds

water level – verifies output

and repeats; Drain closed; Supply 1 ON, HT ON, cold fill ON

even if not heated model)

 

 

 

Supply 2: 5 seconds (Heat on

Display shows ‘SUP2’ (keypad ADD BLEACH LED on)

also)

 

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds

 

 

and repeats; Drain closed; Supply 2 ON, HT ON, cold fill ON

 

 

Supply 3: 5 seconds (Heat on

Display shows ‘SUP3’ (keypad RINSE LED on)

also)

 

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds

 

 

and repeats; Drain closed; Supply 3 ON, HT ON, cold fill ON

 

 

Supply 4: 5 seconds

Display shows ‘SUP4’ (keypad RINSE LED on)

 

 

 

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds

 

and repeats; Drain closed; Supply 4 ON, cold fill ON

 

 

Pause 5 seconds, then Forward

Display shows ‘For’

wash speed – 60 seconds

 

Outputs: Motor operates wash speed forward; drain closed

 

 

 

 

Table 2 (Continued)

18

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232168