Installation and Connection Instructions

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ensure that the machine is installed on a level floor of

 

 

 

 

 

 

 

sufficient strength and that the recommended clearances

 

 

 

 

 

 

 

for inspection and maintenance are provided. Never

 

 

 

 

 

 

 

allow the inspection and maintenance space to be

 

 

 

 

 

 

 

blocked.

 

 

 

 

 

 

Surface

 

 

 

 

 

The machine must be securely fixed on a flat surface (metal base,

 

 

 

 

 

concrete or solid ground). The anchoring is to be done on the

 

 

 

 

 

6 provided places (A) (See Label 1) in the holes on the corner of the

 

 

 

 

base. (See Mounting Bolt Hole Locations)

 

 

 

 

 

The machine must be placed entirely level. For easy maintenance it

 

 

 

A

A

is recommended to keep a minimal distance of 600 mm - 23.62 inch

 

Label 1

between the wall and the back of the machine.

If several machines are placed next to each another, there should be a minimal distance of 30 mm - 1.18 inch between each machine.

 

 

D

E

 

C

F

 

 

 

D

 

B

C

G

 

 

 

A

 

 

Label 2

Anchoring on a metal base

The machines must be fixed on a metal base which is securely anchored on a concrete base. See Label 2.

WFF65/75/100 = WFF65, IWF065, IWF014, CWF065, CWF014, WFF75, IWF074, IWF018, CWF074, CWF018, WFF100, IWF100, IWF025, CWF100, CWF025

WFF135/165 = WFF135, IWF135, IWF030, CWF135, CWF030, WFF165, IWF165, CWF165

A: Bolt M12 (1/2”) (WFF65/75/100), M16 (5/8”) (WFF135/165)

B: Concrete base (WFF65/75/100: 25 cm - 9.48 inch, WFF135/165: 35 cm - 13.77 inch)

C: Washer 40x17x4 (1.57x0.60x0.15)

D: Nut M12 (1/2”) (WFF65/75/100), M16 (5/8”) (WFF135/165)

E: Base of the machine

F: Metal base

G: Bolt M16x60 (5/8” x 2 1/2”)

D

E

C

B

A

Directly on the ground

The machine must be anchored directly on a concrete base. See Label 3.

A: Bolt M12 (1/2”) (WFF65/75/100), M16 (5/8”) (WFF135/165)

B: Concrete base (WFF65/75/100: 25 cm - 9.48 inch, WFF135/165: 35 cm - 13.77 inch)

C: Washer 40x17x4 (1.57x0.60x0.15)

D: Nut M12 (1/2”) (WFF65/75/100), M16 (5/8”) (WFF135/165)

E: Base of the machine

IMPORTANT: Machine bolts should be re-checked on a quarterly basis.

Label 3

24

Page 24
Image 24
Alliance Laundry Systems WFF165, WFF75, WFF135 Installation and Connection Instructions, Surface, Anchoring on a metal base