LOVGeneration II Technical Reference

Service Required Errors

A SERVICE REQUIRED error alternating with YES displays on the computer. After YES is pressed the alarm is silenced. The computer displays an error message from the list below three times with the location of the error. Then, the computer displays SYSTEM ERROR FIXED? YES/NO. If yes is chosen, enter code 1111. If NO is chosen, the system returns to cook mode for 15 minutes then redisplays error until issue is fixed.

Pressing the MIB reset button during any filter function will generate a SERVICE RE- QUIRED error.

This is a list of the service required errors and cause.

ERROR MESSAGE

EXPLANATION

 

Oil not returning to vat quickly. Possible problems: dirty pad, bad

PUMP NOT FILLING

or missing O-rings, tripped or defective filter pump, actuators or

 

linkage.

DRAIN VALVE NOT OPEN

Drain valve failed to open; the valve’s position is unknown.

DRAIN VALVE NOT CLOSED

Drain valve failed to close; the valve’s position is unknown.

RETURN VALVE NOT OPEN

Return valve failed to open; the valve’s position is unknown.

RETURN VALVE NOT CLOSED

Return valve failed to close; the valve’s position is unknown.

MIB BOARD

Problem with CAN communications; check for loose CAN connec-

tions. MIB board failure.

 

AIF BOARD

MIB detects AIF missing; AIF board failure.

ATO BOARD

MIB detects ATO board connection lost; ATO board failure.

HIGH LIMIT FAILURE

High limit circuit has an issue.

AIF PROBE

AIF RTD reading out of range.

ATO PROBE

ATO RTD reading out of range.

TEMP PROBE FAILURE

TEMP Probe reading out of range.

MIB SOFTWARE

Internal MIB software error.

INVALID CODE LOCATION

SD card removed during update.

MISCONFIGURED ENERGY

Energy type in fryer setup is incorrect; set proper energy type gas

TYPE

or electric. Press 1234 to enter setup to properly configure fryer.

RTC INVALID DATE

The date is invalid. Press 1234 to enter setup to properly config-

ure fryer and set proper date.

 