Image 7
Reset

LOVGeneration II Technical Reference

Mode Display Shows status (auto or manual) vat number (when operating valves manuals) and dis- plays error codes.

Vat Selection Selects vat for manual operation of valves.

Manual/Auto Switches fryer from auto to manual operation.

The MIB board.

Reset

Resets system, ensures all valves are closed.

Drain

Opens and closes

Drain drain valves in manual mode.

Return

Opens and closes return valves and turns on filter pump in manual mode.

Manual — Used to toggle between automatic and manual filtration mode. The unit must be in manual mode for the other MIB buttons to operate.

Select — Used to scroll through the vats, which are shown numerically in the LED.

Drain — Used to open and close the drain valve of the vat indicated on the display. When pressed an LED on the button indicates activity: slow blink, awaiting response from AIF; LED illuminated constantly, drain open; no illumination, drain closed.

Return — Used to open and close the return valve on the vat indicated on the display. It also controls the pump. When pressed an LED on the button indicates activity:

blink: awaiting response from AIF,

LED illuminated constantly: drain open,

no illumination: drain closed.

The MIB is mounted behind the left door. See arrow.

The pump operates with a momentary switch. Pressing and holding the return button after the valve is open activates the filter pump. Releasing the button deactivates the pump.

The mode display on the face of the MIB board displays a range of letters, which indicate activity or an error. These codes are listed on the next page.