LOVGeneration II Technical Reference

Problem

Probable Cause

Corrective Action

 

 

A. Ensure the CAN bus system is terminated

 

 

at BOTH ENDS (on the M3000 connector

 

 

J6 and on the ATO board connector J10)

 

 

with a resistor equipped 6-pin connector.

 

 

B. With the computer OFF, press TEMP but-

 

 

ton and ensure the AIF version appears.

 

 

If not, the 24V to the AIF boards may be

 

 

missing. Ensure all 6-pin CAN connectors

 

 

are tight between the M3000 (J6 and J7),

 

 

MIB (J1 and J2), AIF (J4 and J5) and ATO

 

 

(J10) boards.

 

 

C.With the computer OFF, press TEMP but-

 

 

ton and ensure the ATO version appears. If

 

 

not, check the CAN wire harness between

 

 

the AIF board J4 or J5 and the ATO board

 

 

J9 or J10. The ATO fuse on the right side

 

 

of the ATO box may be loose or blown;

 

 

the 110V to the ATO transformer may be

 

 

missing or bad. The J4/J5 connector may

 

 

be loose.

 

 

D.Check to see if MIB has 24V on pins 5 and

MIB board alternat-

Network error on the CAN bus

6 of J2. Check to see if 24V is present on

ing “E” and “vat

communication.

pins 5 and 6 of wire harness plugging into

number and side.”

J4 or J5 of the first AIF board. If 24V miss-

 

 

 

ing, check the pins. Replace the harness if

 

 

necessary.

 

 

E. Check continuity between each color wire

 

 

on the CAN connectors into J7 on the far

 

 

right computer and J10 on back of the ATO

 

 

board (black to black, white to white, and

 

 

red to red) and ensure there is no continu-

 

 

ity between different color wires (black to

 

 

red, red to white, and white to black).

 

 

F. Ensure black computer locator wires are

 

 

connected from ground to correct pin posi-

 

 

tion (see pages 43-47).

 

 

G.Ensure all boards have the corner ground

 

 

wire attached and tightened.

 

 

H.Check for loose locator pin or incorrect

 

 

positioning in J2 of the AIF board. See the

 

 

charts on pages 43-47 of this manual for

 

 

proper pin position.

 

 

I. Bad MIB and/or AIF board.

 

 

J. Broken resistor lead. Unwrap the resistor

 

 

leads and check ends.

9

Page 10
Image 10
Frymaster M3000 LOV Generation II Technical Reference, Problem, Probable Cause, Corrective Action, MIB board alternat