Frymaster manual M3000 Useful Codes, Passwords, LOV Generation II Technical Reference

Models: M3000

1 50
Download 50 pages 41.62 Kb
Page 26
Image 26
M3000 Useful Codes

LOVGeneration II Technical Reference

M3000 Useful Codes

To enter any of the following codes: Press and hold and simultaneously for TEN seconds; three chirps sounds. The computer displays TECH MODE. Enter the codes below to perform this function.

0042 – Reset RECOVERY FAULT CALL SERVICE.

1658 – Change from F° to C°. The computer displays off. Turn the computer on and check temperature to see the temperature scale. If the desired scale is not displayed, repeat.

3322 – Reset Factory Menu. The computer displays COMPLETE, and then off. (NOTE: This will delete any hand-entered menu items.)

1650 – Enter Tech Mode. See page 1-36 to reset passwords and change filter pad time.

1212 – Switch Between Domestic and International Menu. The computer displays

COMPLETE, and then off. (NOTE: This will delete any hand-entered menu items.)

0469 – Reset Filter Stat Data.

The following codes require the removal and reinsertion of the J3 locator plug on the rear of the computer before entering the code.

1000 – Reset CALL TECH Message. Disconnect board locator plug (J10). Reinsert plug. Enter 1000. Computer display switches to off. Remove and then restore power to the computer using the 20-pin plug.

9988 – Reset BADCRC Message. Disconnect board locator plug (J10). Reinsert plug. Enter 9988. Computer display switches to off. Remove and then restore power to the computer using the 20-pin plug. Replace the computer.

The following codes are entered when prompted to do so or from an energy misconfigured exception error.

1111 – Reset SERVICE REQUIRED Message. Enter this when the issue is fixed and you are prompted to enter.

1234 – Enter SETUP MODE from energy misconfigured exception error. (This usu- ally can be done without pressing the filter buttons if an error is displayed.)

Passwords

To enter level one, level two passwords – Press and hold the TEMP and INFO buttons simultane- ously until level 1 or level 2 is displayed. Release the buttons and ENTER Code appears.

1234 – Fryer Setup, Level One, and Level Two.

4321 – Usage Password.