LOV™ Generation II Technical Reference
CODE | ERROR MESSAGE | EXPLANATION | |
|
| A product cook is started on the right side of a split vat | |
E01 | REMOVE DISCARD (Right) | or in a full vat that has a different setpoint other than the | |
|
| current vat temperature. | |
|
| A product cook is started on the right side of a split vat | |
E02 | REMOVE DISCARD (Left) | or in a full vat that has a different setpoint other than the | |
|
| current vat temperature. | |
E03 | ERROR TEMP PROBE FAILURE | TEMP Probe reading out of range. | |
E04 | HI 2 BAD | High limit reading is out of range. | |
E05 | HOT HI 1 | High limit temperature is past more than 410°F (210°C), | |
or in CE countries, 395°F (202°C). | |||
|
| ||
E06 | HEATING FAILURE | A component has failed in the high limit circuit such as | |
computer, interface board, contactor or | |||
|
| ||
E07 | ERROR MIB SOFTWARE | Internal MIB software error. | |
E08 | ERROR ATO BOARD | MIB detects ATO board connection lost; ATO board | |
failure. | |||
|
| ||
|
| Oil not returning to vat quickly. Possible problems: dirty | |
E09 | ERROR PUMP NOT FILLING | pad, bad or missing | |
|
| pump, actuators or linkage. | |
E10 | ERROR DRAIN VALVE NOT OPEN | Drain valve failed to open; the valve’s position is | |
unknown. | |||
|
| ||
E11 | ERROR DRAIN VALVE NOT CLOSED | Drain valve failed to close; the valve’s position is | |
unknown. | |||
|
| ||
E12 | ERROR RETURN VALVE NOT OPEN | Return valve failed to open; the valve’s position is | |
unknown. | |||
|
| ||
E13 | ERROR RETURN VALVE NOT CLOSED | Return valve failed to close; the valve’s position is | |
unknown. | |||
E14 | ERROR AIF BOARD | MIB detects AIF missing; AIF board failure. | |
|
| Cooking computer detects MIB connections lost; | |
E15 | ERROR MIB BOARD | check software version on each computer. If versions | |
are missing, check CAN connections between each | |||
|
| ||
|
| computer; MIB board failure. | |
E16 | ERROR AIF PROBE | AIF RTD reading out of range. | |
E17 | ERROR ATO PROBE | ATO RTD reading out of range. | |
E18 | Not Used |
| |
E19 | M3000 CAN TX FULL | Connection between computers lost. | |
E20 | INVALID CODE LOCATION | SD card removed during update. | |
E21 | FILTER PAD PROCEDURE ERROR | 25 hour timer has expired or dirty filter logic has | |
(Change Filter Pad) | activated. | ||
| |||
E22 | OIL IN PAN ERROR | The MIB has detected oil may be in the pan. | |
E23 | CLOGGED DRAIN (Gas) | Vat did not empty during filtration. | |
E24 | OIL RETURN (level) SENSOR FAILED | Oil return sensor may have failed. | |
(Gas) |
| ||
|
| ||
E25 | RECOVERY FAULT | Recovery time exceeded maximum time limit. | |
E26 | RECOVERY FAULT CALL SERVICE | Recovery time exceeded maximum time limit for two or | |
more cycles. | |||
|
| ||
E27 | LOW TEMP ALARM | Oil temperature has dropped lower than 15°F (8°C) in | |
idle mode or 45°F (25°C) in cook mode. | |||
|
|
27