LOVGeneration II Technical Reference

CODE

ERROR MESSAGE

EXPLANATION

 

 

A product cook is started on the right side of a split vat

E01

REMOVE DISCARD (Right)

or in a full vat that has a different setpoint other than the

 

 

current vat temperature.

 

 

A product cook is started on the right side of a split vat

E02

REMOVE DISCARD (Left)

or in a full vat that has a different setpoint other than the

 

 

current vat temperature.

E03

ERROR TEMP PROBE FAILURE

TEMP Probe reading out of range.

E04

HI 2 BAD

High limit reading is out of range.

E05

HOT HI 1

High limit temperature is past more than 410°F (210°C),

or in CE countries, 395°F (202°C).

 

 

E06

HEATING FAILURE

A component has failed in the high limit circuit such as

computer, interface board, contactor or open-high limit.

 

 

E07

ERROR MIB SOFTWARE

Internal MIB software error.

E08

ERROR ATO BOARD

MIB detects ATO board connection lost; ATO board

failure.

 

 

 

 

Oil not returning to vat quickly. Possible problems: dirty

E09

ERROR PUMP NOT FILLING

pad, bad or missing O-rings, tripped or defective filter

 

 

pump, actuators or linkage.

E10

ERROR DRAIN VALVE NOT OPEN

Drain valve failed to open; the valve’s position is

unknown.

 

 

E11

ERROR DRAIN VALVE NOT CLOSED

Drain valve failed to close; the valve’s position is

unknown.

 

 

E12

ERROR RETURN VALVE NOT OPEN

Return valve failed to open; the valve’s position is

unknown.

 

 

E13

ERROR RETURN VALVE NOT CLOSED

Return valve failed to close; the valve’s position is

unknown.

E14

ERROR AIF BOARD

MIB detects AIF missing; AIF board failure.

 

 

Cooking computer detects MIB connections lost;

E15

ERROR MIB BOARD

check software version on each computer. If versions

are missing, check CAN connections between each

 

 

 

 

computer; MIB board failure.

E16

ERROR AIF PROBE

AIF RTD reading out of range.

E17

ERROR ATO PROBE

ATO RTD reading out of range.

E18

Not Used

 

E19

M3000 CAN TX FULL

Connection between computers lost.

E20

INVALID CODE LOCATION

SD card removed during update.

E21

FILTER PAD PROCEDURE ERROR

25 hour timer has expired or dirty filter logic has

(Change Filter Pad)

activated.

 

E22

OIL IN PAN ERROR

The MIB has detected oil may be in the pan.

E23

CLOGGED DRAIN (Gas)

Vat did not empty during filtration.

E24

OIL RETURN (level) SENSOR FAILED

Oil return sensor may have failed.

(Gas)

 

 

 

E25

RECOVERY FAULT

Recovery time exceeded maximum time limit.

E26

RECOVERY FAULT CALL SERVICE

Recovery time exceeded maximum time limit for two or

more cycles.

 

 

E27

LOW TEMP ALARM

Oil temperature has dropped lower than 15°F (8°C) in

idle mode or 45°F (25°C) in cook mode.

 

 