Troubleshooting the Top Off System
ATO Board
Transformer
Probable Causes
Problem
LOV Generation II Technical Reference
Corrective Action
Auto Filtration MIB and AIF
LOV Generation II Technical Reference
Return
Reset
Drain
LED illuminated constantly drain open no illumination drain closed
Manual Draining, Filling, Filtering with MIB
Error Codes
LOV Generation II Technical Reference
Probable Cause
Troubleshooting the Manual Interface Board MIB
Problem
Corrective Action
Probable Cause
Problem
LOV Generation II Technical Reference
Corrective Action
Problem
Troubleshooting the AIF System AIF
Oil Return Sensor Troubleshooting Gas LOV Fryers
LOV Generation II Technical Reference
Typical sensor-related failures
LOV Generation II Technical Reference
LOV Generation II Technical Reference
M3000 Computer
Overview
Product Buttons
Cook Cycle and Selection Buttons
Filter, Temperature, and Info Buttons
Navigation
Temp Button
Basic Operation
LOV Generation II Technical Reference
duty
Cooking With Multi-Product Display
Mc chick
pull
Q7 Fry Q1 Fry
Cooking With Dedicated Display
fr fries
Qual
LOV Generation II Technical Reference
Changing from Breakfast Setup to Lunch
fr fries
Hash brn
Fr fries
Changing from Lunch Setup to Breakfast
FR FRies
Fr fries
Location in IO manual
LOV Generation II Technical Reference
M3000 Menu Items
Programming
Loading and Updating Software Procedures
LOV Generation II Technical Reference
M3000 Troubleshooting
LOV Generation II Technical Reference
LOV Generation II Technical Reference
LOV Generation II Technical Reference
LOV Generation II Technical Reference
0042 - Reset RECOVERY FAULT CALL SERVICE
Passwords
M3000 Useful Codes
0469 - Reset Filter Stat Data
ERROR MESSAGE
Service Required Errors
This is a list of the service required errors and cause
LOV Generation II Technical Reference
CODE
ERROR MESSAGE
LOV Generation II Technical Reference
EXPLANATION
LOV Generation II Technical Reference
Fryer Setup Mode
Tech Mode
WORDS
LOV Generation II Technical Reference
4. Press the 9 1 yes button The computer displays ENTER CODE 5. Enter
16. Enter the date using the number buttons
LOV Generation II Technical Reference
NORMAL OPERATION RESUMES
Filter Error Flow Chart
LOV Generation II Technical Reference
for SYST EM ER ROR FIX ED? YES
JIB solenoid is not opening
Troubleshooting
RTI-equipped Systems
RTI pump is not operating or JIB is not filling
LOVGeneration
Bulk Oil LOV Wiring
II Technical Reference
M IB J6
LOV Generation II Technical Reference
Oil Disposal and Fill with RTI-equipped Systems
Warning Do not add HOT or USED oil to the JIB
New Oil Tank
Frymaster LOV Fryer and RTI Bulk Oil System Plumbing Schematic
LOV Generation II Technical Reference
Waste Oil Tank
DISPOSE TO WASTE
RTI LOV Test Quick Reference
DISPOSE TO WASTE, REFILL VAT FROM BULK
LOV Generation II Technical Reference
FILTER NOW? YES/NO, CONFIRM YES/NO, or SKIM VAT cannot be displayed
FILL VAT FROM BULK
Solenoid closed
Other factors that may not allow fill jug from bulk
8. CYCLE POWER TO ENTIRE FRYER SYSTEM see section above
Board and Computer Replacement
ATO Board, LON Gateway, ATO Pump Relay, and Transformer Replacement
Readdress All Boards
LOV Generation II Technical Reference
MIB Replacement
AIF Replacement
Cover
ATO Pump Replacement
M3000 Computer Replacement
LOV Generation II Technical Reference
LOV Electric Fryer
Wiring Diagrams
LOV Generation II Technical Reference
START OF 6-WIRE DATA & POWER
LOV Gas Fryer
LOV Generation II Technical Reference
Middle
Data Network Flow Chart
LOV Generation II Technical Reference
Right
ATO Automatic Top Off Pin Positions and Harnesses
Pin Positions
LOV Generation II Technical Reference
LOV Generation II Technical Reference
MIB Manual Interface Board Pin Positions and Harnesses
From RTI “Waste Tank Full
MIB Manual Interface Board Display Diagnostics
LOV Generation II Technical Reference
FV Return
AIF Auto Intermittent Filtration Actuator Board Pin Positions
LOV Generation II Technical Reference
Oil Level Sensor
M3000 Board, Harnesses, and Pin Positions
LOV Generation II Technical Reference
English
Service Center 800 551-8633 or
Frymaster L.L.C 8700 Line Avenue, Shreveport, LA
February