Frymaster M3000 manual LOV Generation II Technical Reference

Models: M3000

1 50
Download 50 pages 41.62 Kb
Page 24
Image 24

LOVGeneration II Technical Reference

Problem

Probable Causes

Corrective Action

 

 

This display is normal when the fryer

 

 

is first turned on while in the melt cycle

 

 

mode. To bypass the melt cycle press

M3000 display shows

 

and hold either #1 or #2 product button

Frypot temperature is between

under the LCD display until a chirp is

low temp alternating

180°F (82°C) and 315°F (157°C).

heard. The computer displays EXIT

with MLT-CYCL.

 

 

MELT alternating with YES and NO.

 

 

Press the #1 YES button to exit melt.

 

 

If the display continues, the fryer is not

 

 

heating.

 

 

 

M3000 display shows

Defective SD card.

Replace card with another card.

ERROR RM SDCRD

 

 

 

 

 

A. This indicates a problem within the

 

A. Problem with the temperature

temperature measuring circuitry.

M3000 display shows

measuring circuitry including the

Check resistance of probe, if faulty

probe.

replace probe.

TEMP PROBE

 

B. Swap the computer wiring harness

FAILURE.

 

B. Damaged computer wiring

with one known to be good. If

 

harness or connector.

problem is corrected, replace the

 

 

harness.

 

 

 

MAINT FILTER (Manual

Temperature too low.

Ensure fryer is at setpoint before starting

Filter) won’t start.

MAINT FILTER.

 

 

 

 

 

 

Remove and discard product. Press a

M3000 display shows

In non-dedicated mode, a product is

cook button under the display with the

dropped that has a different setpoint

error to remove the error. Reset the

REMOVE DISCARD.

that the current vat temperature.

setpoint of the vat before trying to cook

 

 

product.

 

 

 

 

 

Turn off the vat with the problem. This

 

 

error is displayed if the fryer loses its

M3000 display shows

Failed computer, failed interface

ability to heat oil. It is also displayed

when the oil temperature is above

HEATING FAILURE.

board, open high-limit thermostat.

450°F (232°C) and the high-limit

 

 

 

 

thermostat has opened, halting the

 

 

heating of the oil.

 

 

 

Computer will not go into

 

 

program mode or some

Failed computer.

Replace computer

buttons do not actuate.

 

 

 

 

 

M3000 display shows HI

 

This is displayed during a test of the

Computer in high-limit test mode.

high-limit circuit to indicate if the high-

2 BAD.

 

limit has failed.

 

 

 

 

 

M3000 display shows

 

This is displayed to indicate the high-

HELP HI-2or HIGH

Failed high-limit.

limit has failed.

LIMIT FAILURE.

 

 

 

 

 

 

23

Page 24
Image 24
Frymaster M3000 manual LOV Generation II Technical Reference