LOVGeneration II Technical Reference

Problem

Probable Causes

Corrective Action

 

 

 

 

 

A. Check to see that fryer is heating.

 

 

Fryer temperature must be at

 

 

setpoint. Check ATO probe

 

 

resistance. If probe is bad, replace

 

 

the probe.

 

 

B. Ensure that the oil in the JIB is

 

 

above 70°F (21°C).

 

 

C. With the computer OFF, press

 

A. Probe temperature lower than

TEMP button and ensure the

 

ATO version appears. If not,

 

setpoint.

 

the connection between the AIF

 

 

 

B. Oil is too cold.

and the ATO board may be bad.

 

Ensure the 6-pin CAN connectors

 

 

 

C. Bad Connection.

are tight between AIF (J4 and J5)

 

and ATO (J10) boards.

 

 

Frypots won’t top off.

D. ATO board power loss.

D. Power to the ATO board has been

cut off. Restore power to the board

 

 

 

E. Failed transformer/harness.

and clear any service required

 

errors.

 

 

 

F. ATO pump failed.

E. Ensure transformer in ATO box is

 

functioning properly. Check power

 

 

 

G. Failed ATO board.

from transformer to ATO board.

 

Ensure all harnesses are plugged

 

 

 

 

securely into place.

 

 

F. Ensure pump is operational.

 

 

Check voltage to pump. Replace

 

 

the pump if defective.

 

 

G. Check for proper voltages using the

 

 

pin position charts found on pages

 

 

43-47. If ATO found defective,

 

 

replace ATO board and clear any

 

 

errors.

 

 

A. Ensure all wiring harnesses are

One vat tops off but other

A. Loose wire connection.

securely connected to ATO board

 

and solenoids.

vats fail to top off.

 

B. Actuator issue.

B. Check return actuator to ensure

 

 

 

actuator is functional.

 

 

 

Incorrect vat tops off.

A. Wired incorrectly.

A. Check wiring.

 

B. Flexlines connected to wrong vat.

B. Switch flexlines to correct vat.

 

 

 

 

 

 

 

 

A. Clear filter error properly. When

 

 

change filter pad YES/

 

A. Filter error exists.

NO is displayed, do NOT press

 

any button until the pan has been

One vat doesn’t top off.

B. Actuator, pump, loose connection,

removed for at least thirty seconds.

After thirty seconds have elapsed,

 

 

RTD or ATO issue.

the computer returns to OFF or last

 

 

display.

 

 

B. Check actuator, ATO pump, wire

 

 

connections, RTD and ATO board.

 

 

 