Error Codes

LOVGeneration II Technical Reference

Error Codes

1L, 1r - 5L, 5r — Numbers correspond to vats: “L” indicates the left side of a split vat. “r” indicates a full vat or the right side of a split vat.

A — Auto mode: auto filtration enabled.

E — Drain or return valve not in desired state: display alternates between E and vat number. (Ensure actuator is plugged in and in the home position.)

n — Network Error: An “n” displays for 10 seconds if no communication is received from the cooking computer within ten seconds after a power on.

P — Pan switch: filter pan is not in place or not sensed. Auto Filtration disabled.

r — Reset: r alternating with a vat number indicates that the MIB board is resetting. If r is displayed without alternating with a vat number, a problem may exist with the MIB board itself.

Three horizontal lines — temperature sensor: sensor did not detect that the vat was full during auto filtration.

Manual Draining, Filling, Filtering with MIB

1

2

3

1.Press the M button, which switches the board to manual. The display becomes the number of the vat to be controlled manually.

2.Press the vat selector button until the desired vat number is displayed.

3.Press the drain button to drain the oil or the press and hold the return button to return oil to the vat displayed. Opening the drain and pressing and holding the return button after valve is open allows filtration.

4.Pressing the M button again returns the board to automatic mode.