Loading and Updating Software Procedures

LOVGeneration II Technical Reference

Loading and Updating Software Procedures

Updating the software takes approximately 20 minutes. To update the software, follow these steps:

1.Switch all computers to OFF. Press the TEMP button to check current M3000/MIB/AIF/ATO software version.

2.Remove the two screws on the left side cover plate of the M3000 board.

3.With the computer folded down, insert the SD card into the slot on the left side of the M3000. The contacts on the card should face down and the notch should appear on the bottom right (see pictures below).

4.Once inserted, UPGRADE IN PROGRESS appears on the left display and WAIT on the right.

5.The display then changes to CC UPDATING on the left and the percentage completed appears on the right. The display counts up to 100 on the right, changing to a flashing BOOT. DO NOT REMOVE

THE CARD UNTIL THE DISPLAY PROMPTS TO DO SO IN STEP 8.

6.Then, UPGRADE IN PROGRESS is displayed on the left display and WAIT on the right again, followed by COOK HEX, mib HEX, aif HEX ending with aTO HEX displayed on the left and the percentage complete on the right.

7.The display then changes to REMOVED SD CARD on the left and 100 on the right.

8.Remove the SD card using the fingernail slot on the top of the SD card.

9.Once the SD card is removed the display changes to CYCLE POWER.

10.Cycle the control power using the hidden reset switch behind the right control box (see page 38). HOLD

THE SWITCH FOR 10 SECONDS ENSURING THE MIB BOARD HAS POWERED FULLY DOWN.

11.M3000 CAN TX FULL (a SERVICE REQUIRED error) may appear while computers are rebooting. Press YES at the prompt to cancel alarm. A flashing BOOT is displayed on the remaining computers while the program is transferred.

12.When the update is complete, the M3000 displays OFF. The MIB display will remain blank while software is loading, changing to show the vat numbers. Once the LEDs stop blinking, press YES to SYSTEM ERROR FIXED? Enter 1111. The MIB board will display A.

13.Cycle the control power using the hidden reset switch behind the right control box again. ENSURE

THE SWITCH IS HELD FOR 10 SECONDS. WAIT ANOTHER 20 SECONDS UNTIL THE MIB BOARD HAS FULLY RESET BEFORE CONTINUING.

14.With the computer displaying OFF, VERIFY software update by pressing the TEMP button to check updated M3000/MIB/AIF/ATO version on each computer. IF ANY BOARDS DID NOT UPDATE, REPEAT THE PROCESS STARTING WITH STEP 3.

Insert the SD card with contacts fac- ing down.