Patch 86222-25 For Rapier Switches and AR800 Series Modular Switching Routers

35

Features in 86222-01

Patch file details for Patch 86222-01 are listed in Table 22.

Table 22: Patch file details for Patch 86222-01.

Base Software Release File

86s-222.rez

 

 

Patch Release Date

11-Jul-2001

 

 

Compressed Patch File Name

86222-01.paz

 

 

Compressed Patch File Size

187124 bytes

 

 

Patch 86222-01 includes the following enhancement for Software Release 2.2.2:

PCR: 01100 Module: DHCP

Network affecting: No

The DHCP server identified the wrong port numbers for incoming DHCP requests causing DHCP replies to be sent to the wrong port. This issued has been resolved.

PCR: 01102

Module: IPG

Network affecting: No

The IP flow cache occasionally generated a watchdog fatal error. This issued has been resolved.

PCR: 01102

Module: SWI

Network affecting: No

Deleting entries from an L3 table occasionally resulted in a watchdog fatal error. This issue has been resolved.

PCR: 01106

Module: PKI

Network affecting: No

PKI enrolment no longer causes message validation to fail.

PCR: 01119

Module: IPV6

Network affecting: No

Repeated addition and deletion of an address with the VALID parameter set to or from an IPV6 interface caused a fatal error. This issue has been corrected. The VALID parameter specifies the life of the address, and defaults to INFINITE. The address is deleted when the lifetime expires. The PREF parameter specifies the time that the address is the preferred address of the interface, and defaults to INFINITE. PREF must be less than or equal to VALID. IPV6 now checks and ensures that if either PREF or VALID is specified, PREF is less than or equal to VALID. When an address is deleted the timers are now correctly cleared.

PCR: 01120

Module: IPG

Network affecting: No

IP sometimes passed the wrong port number to PIM, causing PIM to process the wrong port number in its routing table. This issued has been resolved.