Patch 86222-27 For Rapier Switches

5

PCR: 03526

Module: SWI

Level: 3

The Switch MIB did not show the correct dot1StpPriority value. This issue has been resolved.

PCR: 03531

Module: SWI

Level: 3

After creating a trunk group, the activity LEDs did not flash unless the configuration was used at reboot. This issue has been resolved so that the LEDs flash correctly whenever a trunk group is created.

PCR: 03572

Module: STP

Level: 3

The dot1dStpPortForwardTransitions value in the dot1dBridge MIB was not incremented correctly when STP transitioned a port to the Forwarding state. This issue has been resolved.

PCR: 03574

Module: STP

Level: 3

The dot1dStpInfoTopChanges value in the dot1dBridge MIB was not incremented correctly when a topology change was detected by the bridge. This issue has been resolved.

PCR: 03576

Module: IPG

Level: 2

When the device received a route from two separate sources to the same destination network, RIP only used the metric value when selecting the best route. RIP now selects the route by lowest preference value, or if they are the same, by the metric.

Features in 86222-25

Patch file details are listed in Table 3:

Table 3: Patch file details for Patch 86222-25.

Base Software Release File

86s-222.rez

 

 

Patch Release Date

15-April-2003

 

 

Compressed Patch File Name

86222-25.paz

 

 

Compressed Patch File Size

443760 bytes

 

 

Patch 86222-27 for Software Release 2.2.2 C613-10319-00 REV Z

Patch 86222-25 includes all issues resolved and enhancements released in previous patches for Software Release 2.2.2, and the following enhancements:

PCR: 02300

Module: Firewall

Network affecting: No

If the command ADD FIREWALL POLICY RULE SOURCEPORT=ALL was executed, a value of “65535” was incorrectly displayed for the SOURCEPORT parameter for that rule in the SHOW FIREWALL POLICY command. This issue has been resolved.

PCR: 02400

Module:

Network affecting: No

 

CORE,FFS,FILE,INSTALL,SCR

 

If a problem occurred with NVS, some critical files were lost. As a result, the equipment was forced to load only boot ROM software at boot time. This patch combined with the new version of the boot ROM software (pr1-1.2.0 for the AR700 series) resolves this issue.

Page 5
Image 5
Allied Telesis 86222-27 PCR Module STP Level, PCR Module Firewall Network affecting No, PCR Module Network affecting No