Installation & Safety Guide 5
Selecting a Site
Before you install the switch, review the following considerations about its
location.
■The switch requires an ambient temperature range of 0 º C to 40º C
(32º F to 104º F).
■There should be adequate airflow around the switch and its vents.
■The site should be dust-free and without moisture.
■Humidity can be from 5% to 80% non-condensing.
■You need a reliable and earthed (grounded) power supply source, preferably
dedicated and filtered.
■Cabling must not be exposed to sources of electrical noise, such as radio
transmitters, broadband amplifiers, power lines, electric motors, and
fluorescent fixtures.
■Switch ports are suitable for connection to intra-building or non-exposed
cabling is required.
■Related network devices can be connected to the switch but cannot exceed
maximum cable lengths specified in the Hardware Reference.
■You may need to remove cabinet doors to accommodate cords and cables.
■Ensure easy access to the switch’s power and cable connections.