Allied Telesis SB251-10 Features in SB251-06, Features in SB251-05, Module SWI, SYSR, Level

Models: SB251-10

1 14
Download 14 pages 40.94 Kb
Page 6
Image 6
Features in SB251-06

6

Patch Release Note

The PORT parameter of the SET STP PORT command specifies either all the ports in a trunk group, or none of the ports in a trunk group.

The STPFORWARD parameter has been added to the ENABLE SWITCH and DISABLE SWITCH commands. If STPFORWARD is enabled, and there is no enabled STP instance, then the switch will forward all received BPDUs. If STPFORWARD is enabled, and an STP instance is enabled, then STPFORWARD will be disabled by default and a message will be generated.

The SHOW SWITCH command now shows the status of the BPDU Forwarding feature.

PCR: 03401

Module: SWI

An enhancement has been made to the Test module to optimise the reception of the loopbacked packets that are used to confirm operation of the switch ports.

Features in SB251-06

Patch file details are listed in Table 5.

Table 5: Patch file details for Patch SB251-06.

Base Software Release File

sb-251.rez

 

 

Patch Release Date

10-Apr-2003

 

 

Compressed Patch File Name

sb251-07.paz

 

 

Compressed Patch File Size

79684 bytes

 

 

Patch SB251-06 includes all issues resolved and enhancements released in previous patches for Software Release 2.5.1, and the following enhancements:

PCR: 03340

Module: SWI, SYSR

Level: 1

After a power cycle, or a reboot command, the SwitchBlade would occasionally repeatedly restart if it had two active controller cards. Also, the Slave controller card would sometimes not take over if the Master controller card failed.

Features in SB251-05

Patch file details are listed in Table 6.

Table 6: Patch file details for Patch SB251-05.

Base Software Release File

sb-251.rez

 

 

Patch Release Date

31-Mar-2003

 

 

Compressed Patch File Name

sb251-05.paz

 

 

Compressed Patch File Size

71096 bytes

 

 

Patch SB251-10 for Software Release 2.5.1 C613-10361-00 REV J

Page 6
Image 6
Allied Telesis SB251-10 manual Features in SB251-06, Features in SB251-05, Module SWI, SYSR, Level