10 | Patch Release Note |
PCR: 03142 | Module: SWI | Level: 1 |
If a BIST was run at low temperatures, for example 5 or 10 degress celcius, on a G8 card, then a watchdog timer restart could occur. The switch now checks for the real course of the external interrupts that occur when running BIST.
PCR: 03148 | Module: IPG | Level: 3 |
If the Gratuitous ARP feature was enabled on an IP interface, and an ARP packet arrived, (either ARP request, or reply) that had a Target IP address that was equal to the SenderIP address, then the ARP cache was not updated with the ARP packet’s source data. This issue has been resolved.
PCR: 03191 | Module: SWI | Level: 1 |
If two line cards were inserted in quick succession, then a software restart could occasionally occur. This issue has been resolved.
PCR: 03192 | Module: SWI | Level: 2 |
When the
Features in SB251-02
Patch file details are listed in Table 9:
Table 9: Patch file details for Patch
Base Software Release File | |
|
|
Patch Release Date | |
|
|
Compressed Patch File Name | |
|
|
Compressed Patch File Size | 48608 bytes |
|
|
Patch
PCR: 02553 | Module: SWITCH | Network affecting: No |
64 bit MIB counters were not incremented or cleared for port interfaces. This issue has been resolved.
PCR: 02574 Module: DVMRP | Network affecting: No |
Some change actions, and the resending of prune messages were not operating correctly. This issue has been resolved.
PCR: 02582 | Module: SWI | Network affecting: No |
Pause flow control is now disabled by default on all ports. This improves performance of the switch when it is congested.
Patch