4.10.1. MEMORY 1

CONTROLLERS

4.10.1. MEMORY 1

I/O port/memory is A

Sub-Register address is from 00 to 255

Sub-Register definitions

00This location should be set to FFh i f memory initialization is required. During the power up sequence this location is checked for software revision. If FFh is encountered then all memories are reset to factory condition. User memory is not

affected during initialization. Normally you should not write into this location. You can read this location without affecting the CP7317RS.

01I/O definition for digital port 1. Define if pin is Input or Output. If bit is set to 1 then this pin is Input if bit is set to 0 then this pin is output.

02I/O definition for digital port 2. Define if pin is Input or Output. If bit is set to 1 then this pin is Input if bit is set to 0 then this pin is output.

03I/O definition for digital port 3. Define if pin is Input or Output. If bit is set to 1 then this pin is the input if the bit is set to 0 then this pin is the output.

04I/O definition for digital port 4. Define if pin is Input or Output. If the bit is set to 1 then this pin is the input if

the bit is set to 0 then this pin is output.

05 Set baud rate for RS-232 communication.

1300

2600

31200

42400

54800

69600

7Custom baud rate

06Custom baud rate setup. Sub- registers 6 and 7 are used to define custom baud rate. This is usually not required however if it is absolutely necessary to set up non-standard

 

baud rate (as could be in case of

 

MIDI) then contact factory for

 

additional instructions. Register 5

 

must be set to 07h for this custom

 

baud rate to operate.

07

Custom baud rate setup.

08Not available/ Do not read or write into this location.

09Not available/ Do not read or write into this location.

10Unit id number. Any number from 1 to 255. This id number is used during control of multiple CP7317RS units. If the id number is set to 1 then unit will respond to all commands. Id number is factory set to 1

11Not available / Do not read or write into this location.

12Not available / Do not read or write into this location.

13Not available / Do not read or write into this location.

14Not available / Do not read or write into this location.

15Not available / Do not read or write into this location.

16These 8 locations are used to store feedback codes for commands that are properly executed.

.

Factory default is “OK”. To disable

 

feedback set sub-register 16 to FFh.

.

 

23End of feedback code for OK

24These 8 locations are used to store feedback code for command that was not properly

.

executed. Factory setting is “ERR”.

 

To disable feedback set sub-register

 

16 to FFh.

.

 

31End of feedback code for ERR

32Power up status of relays on port 1. If bit is set to 0 then relay will be closed on power up. If bit is set to 1 then relay will be open on power up.