4.10.1. MEMORY 1
I/O port/memory is A
00This location should be set to FFh i f memory initialization is required. During the power up sequence this location is checked for software revision. If FFh is encountered then all memories are reset to factory condition. User memory is not
affected during initialization. Normally you should not write into this location. You can read this location without affecting the CP7317RS.
01I/O definition for digital port 1. Define if pin is Input or Output. If bit is set to 1 then this pin is Input if bit is set to 0 then this pin is output.
02I/O definition for digital port 2. Define if pin is Input or Output. If bit is set to 1 then this pin is Input if bit is set to 0 then this pin is output.
03I/O definition for digital port 3. Define if pin is Input or Output. If bit is set to 1 then this pin is the input if the bit is set to 0 then this pin is the output.
04I/O definition for digital port 4. Define if pin is Input or Output. If the bit is set to 1 then this pin is the input if
the bit is set to 0 then this pin is output.
05 Set baud rate for
1300
2600
31200
42400
54800
69600
7Custom baud rate
06Custom baud rate setup. Sub- registers 6 and 7 are used to define custom baud rate. This is usually not required however if it is absolutely necessary to set up
| baud rate (as could be in case of |
| MIDI) then contact factory for |
| additional instructions. Register 5 |
| must be set to 07h for this custom |
| baud rate to operate. |
07 | Custom baud rate setup. |
08Not available/ Do not read or write into this location.
09Not available/ Do not read or write into this location.
10Unit id number. Any number from 1 to 255. This id number is used during control of multiple CP7317RS units. If the id number is set to 1 then unit will respond to all commands. Id number is factory set to 1
11Not available / Do not read or write into this location.
12Not available / Do not read or write into this location.
13Not available / Do not read or write into this location.
14Not available / Do not read or write into this location.
15Not available / Do not read or write into this location.
16These 8 locations are used to store feedback codes for commands that are properly executed.
. | Factory default is “OK”. To disable |
| feedback set |
. |
|
23End of feedback code for OK
24These 8 locations are used to store feedback code for command that was not properly
. | executed. Factory setting is “ERR”. |
| To disable feedback set |
| 16 to FFh. |
. |
|
31End of feedback code for ERR
32Power up status of relays on port 1. If bit is set to 0 then relay will be closed on power up. If bit is set to 1 then relay will be open on power up.