DISTRIBUTION AMPLIFIERS
cause harmful interference to radio
MECHANICAL | Audio |
|
|
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
∙Any changes or modifications to the unit not expressly approved by Altinex, Inc. could void the user’s authority to operate the equipment.
ABOUT YOUR DISTRIBUTION AMPLIFIER 2
Material
Finish
Top Panel
Height (inches)
Width (inches)
Depth (inches)
Weight (pounds)
Ship Weight (pounds)
T° Operating
T° Maximum
Humidity
MTBF (calculations)
0.1” Al
Gray
Lexan
1.75in (44mm)
8.50in (216mm)
4.93in (125mm)
2.0lbs. (0.91kg)
4.0lbs. (1.81kg)
50°C
50%
40,000 hrs
The
The audio amplifier is designed to provide six buffered and amplified outputs for both left and right channels. The input signals are isolated to prevent ground loops. The input termination is switch selectable to either be 600 Ohms or high impedance.
The
TECHNICAL SPECIFICATIONS | 3 | |
|
|
|
FEATURES/DESCRIPTION | Audio |
|
|
|
|
GENERAL |
|
|
No. of Inputs | 1 |
|
Input Connector | One 3.5 mm |
|
| Terminal Block |
|
No. of Outputs | 6 |
|
Output Connector | Six 3.5mm Terminal |
|
| Blocks |
|
Compatibility | Stereo or Mono Audio |
Table 1.
Table 2.
ELECTRICAL | Audio |
|
|
Input Signals |
|
Level | 10 V |
Impedance | 600 Ohms or high |
| impedance |
Type | Differential input |
| isolated from GND |
Output Signals |
|
Level | 10V |
Impedance | Low – drives 600 Ohms |
Type | Differential input |
| isolated from GND |
Gain | 0 dB unbalanced, +6dB |
| balanced |
Frequency Compatibility |
|
Typical Bandwidth | 10Hz – 20kHz |
Power |
|
Internal Power Supply | |
| |
Power Consumption | 10 watts max |
Table 3.
3